{"product_id":"pocket-conductometer-cond-3110-set-kt27-kt27","title":"Pocket conductometer Cond 3110-Set, -5 - +105°C, H 180 x W 80 x D 55 mm","description":"\u003cp\u003ePocket conductometer Cond 3110-Set, -5 - +105°C, H 180 x W 80 x D 55 mm, incl. meter, 4-pol conductivity electrode TetraCon®325 (measuring range 0.001 to 1000 mS\/cm), professional case, stand, beaker, conductivity test solutions 1413 µS\/cm\u003c\/p\u003e\n\u003c!-- CARLROTH_PRODUCT_DETAILS_V7 --\u003e\n\u003cdiv class=\"tabbody ProductDetailsComponent\"\u003e\n\u003cdiv class=\"row\" style=\"display:flex; flex-wrap:wrap; width:100%; max-width:100%; margin:10px 0; gap:4px;\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-6\" style=\"flex:0 0 45%; max-width:45%; box-sizing:border-box; margin:10px 0; margin-left:-2.5%; \"\u003e\n\n\n\u003c!--superDetailElements --\u003e\n\u003cdiv class=\"item\" style=\"word-wrap:break-word; overflow-wrap:anywhere; hyphens:auto; \"\u003e\n\u003cdiv class=\"details-container\"\u003e\n\n\u003cp style=\"font-size:0.95em; line-height:1.5; margin:12px 0; word-wrap:break-word; overflow-wrap:anywhere; white-space:normal; \"\u003eRobust and waterproof conductivity meter with parallel temperature display.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-container\"\u003e\n\n\u003cdiv\u003e\u003cul style=\"margin:10px 0; padding-left:20px; \"\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003e1-point calibration (freely adjustable calibration standard)\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eNon-linear function for high-purity water and natural water (nLF)\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eSelectable reference temperature\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- OtherDetailElements --\u003e\n\u003c!-- Note --\u003e\n\n\n\u003c!-- Base product name --\u003e\n\n\u003c!-- DetailElements --\u003e\n\n\n\u003c!-- DeliveryText --\u003e\n\u003cdiv\u003e\n\u003cb\u003eDelivery incl.\u003c\/b\u003e TetraCon\u003csup\u003e®\u003c\/sup\u003e 325 four-pole conductivity measuring cell, professional case with integrated measuring space and separate pockets for accessories, tripod, measuring beaker, test solutions (1413 μS\/cm) and batteries.\u003c\/div\u003e\n\u003c!-- printCatalogLink --\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-md-6\" style=\"flex:0 0 55%; max-width:55%; box-sizing:border-box; margin:10px 0; margin-left:-3%; \"\u003e\n\u003cdiv class=\"product-classifications\"\u003e\n\u003cdiv class=\"headline\" style=\"font-weight:bold; font-size:1.2em; margin-bottom:10px;\"\u003eTechnical Information\u003c\/div\u003e\n\u003ctable class=\"table\" style=\"; table-layout:fixed; word-break:normal; overflow-wrap:break-word; width:100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eType\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\tCond 3110-set \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eSensor\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\tTetraCon\u003csup\u003e®\u003c\/sup\u003e 325 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eParameters\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\tconductivity salinity temperature \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eConductivity measuring range\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t0 µS\/cm to 1000 mS\/cm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eConductivity resolution\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\tautomatic (0.1 µS\/cm - 1 mS\/cm) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eConductivity accuracy\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t±0.5% of the measured value \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eCalibration points\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t1 (standard and user-defined) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eReference temperature conductivity\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t+20 \/ +25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eSalinity measuring range\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t0 to 70 psu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eSalinity resolution\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t0.1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eTemperature measuring range\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t-5 to +105 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eTemperature resolution\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t0.1 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eTemperature accuracy\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t±0.1 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eL x W x H\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t180 x 80 x 55 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003ePower supply\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t4x battery Mignon\/AA 1.5 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"margin-top:1.5rem;\"\u003e\n  \u003ca href=\"https:\/\/www.carlroth.com\/medias\/BA-ART-355630-EN.pdf?context=bWFzdGVyfGluc3RydWN0aW9uc3w0MDE2NjN8YXBwbGljYXRpb24vcGRmfGFXNXpkSEoxWTNScGIyNXpMMmhrWkM5b05USXZPRGs1TVRBMk5EYzRORGt5Tmk1d1pHWXwzNzc2ZDY4MGUyNmNkOGNiNjM1YjQyYzUxYWVlYmEwNDk1YmVhNWVlMzhjYmU1NTkzMjljZTJmMjg2ZGUxYTcz\" target=\"_blank\" rel=\"noopener noreferrer\" download style=\"display:inline-flex; align-items:center; gap:.65rem; text-decoration:none; color:#000; font-weight:600; font-size:1rem;\"\u003e\n    \u003csvg style=\"width:1.65rem;height:1.65rem;color:#dc2626;flex-shrink:0;\" viewbox=\"0 0 384 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" aria-hidden=\"true\"\u003e\n      \u003cpath d=\"M64 0C28.7 0 0 28.7 0 64V448c0 35.3 28.7 64 64 64H320c35.3 0 64-28.7 64-64V160H256c-17.7 0-32-14.3-32-32V0H64z\" fill=\"#ffffff\" stroke=\"currentColor\" stroke-width=\"32\"\u003e\u003c\/path\u003e\n      \u003cpath d=\"M256 0V128H384L256 0z\" fill=\"currentColor\"\u003e\u003c\/path\u003e\n      \u003ctext x=\"192\" y=\"380\" font-family=\"Arial, Helvetica, sans-serif\" font-size=\"110\" font-weight=\"bold\" fill=\"currentColor\" text-anchor=\"middle\"\u003ePDF\u003c\/text\u003e\n    \u003c\/svg\u003e\n    Technical Documentation (PDF)\n  \u003c\/a\u003e\n\u003c\/div\u003e","brand":"Carl Roth","offers":[{"title":"1 pc(s) \/ 1 piece","offer_id":56183240687948,"sku":"KT27.1","price":1360.95,"currency_code":"EUR","in_stock":true},{"title":"1 pc(s) \/ 6+ pieces","offer_id":56183240720716,"sku":"KT27.1","price":1360.95,"currency_code":"EUR","in_stock":true},{"title":"1 pc(s) \/ 24+ pieces","offer_id":56183240753484,"sku":"KT27.1","price":1360.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/4827\/7068\/files\/KT27-1-01-1000Wx1000H_473f8f8f-2be7-4f9f-a6dc-b18fd48e09d5.jpg?v=1766485183","url":"https:\/\/www.luminixhealth.com\/de-de\/products\/pocket-conductometer-cond-3110-set-kt27-kt27","provider":"Luminix Health","version":"1.0","type":"link"}