{"product_id":"stammopur-dr-8-cleaning-and-disinfecting-agent-concentrate-2-liter","title":"STAMMOPUR DR 8 Cleaning and disinfecting agent – concentrate, 2 liter","description":"Instruments - Disinfection\u003cbr\u003ewith intensive cleaning in ultrasonic bath \u003cbr\u003eVAH-certified CE 0124\u003cbr\u003e\u003cbr\u003eAt a glance\u003cbr\u003e- Concentrate\u003cbr\u003e- Developed for use in an ultrasonic bath\u003cbr\u003e- Short-term disinfection in an ultrasonic bath\u003cbr\u003e- Very high cleaning effect in the ultrasonic bath\u003cbr\u003e- Very high material compatibility\u003cbr\u003e- Aldehyde-, phenol- and chlorine-free\u003cbr\u003e- Bactericide, Batherculocide, Levurocide\u003cbr\u003e- Virucide against vaccinia, BVDV, Papova, Adeno,\u003cbr\u003eHBV, HCV, HIV, avian influenza A virus H5N1\u003cbr\u003e- Extended service life of 3 days*\u003cbr\u003e- Odourless\u003cbr\u003e\u003cbr\u003eGeneral information\u003cbr\u003eSTAMMOPUR DR 8 is designed for manual instrument disinfection\u003cbr\u003ewith simultaneous intensive cleaning in an ultrasonic bath\u003cbr\u003eand for non-fixing wet storage.\u003cbr\u003eSTAMMOPUR DR 8 causes short ultrasonic treatment times\u003cbr\u003eat low application concentration and is gentle on\u003cbr\u003ethus particularly highly sensitive instruments. The preparation time\u003cbr\u003eis shortened, the instruments stand faster\u003cbr\u003eavailable again.\u003cbr\u003e\u003cbr\u003eMaterial compatibility\u003cbr\u003eSTAMMOPUR DR 8 has a very high material compatibility,\u003cbr\u003eis suitable for parts made of metal, glass, porcelain,\u003cbr\u003eceramic and plastic and has a corrosion protection\u003cbr\u003efor ferrous metals. No optics, light guides and\/or glued\u003cbr\u003eTreat parts in an ultrasonic bath.\u003cbr\u003eFor endoscopes and accessories the suitability recommendations are\u003cbr\u003ethe companies Karl Storz GmbH and Richard Wolf GmbH\u003cbr\u003ebefore. The information provided by the instrument manufacturers can be obtained from\u003cbr\u003eProcessing with STAMMOPUR DR 8, especially in the\u003cbr\u003eUltrasonic bath, to be strictly observed.\u003cbr\u003e\u003cbr\u003eDosage and application times\u003cbr\u003eApplication in an ultrasonic bath\u003cbr\u003eBactericide, Batherculocide, Levurocide\u003cbr\u003evaccinia, BVDV, HBV, HCV, HIV, H5N1\u003cbr\u003e2 % - 5 minutes**\u003cbr\u003ePapova 2 % - 10 minutes**\u003cbr\u003eAdeno 3 % - 15 minutes**\u003cbr\u003eDisinfection without ultrasound\u003cbr\u003e1 % - 60 min (bactericidal, levurocidal)\u003cbr\u003eadditionally effective against\u003cbr\u003evaccinia, BVDV, Papova, HBV, HCV, HIV, H5N1\u003cbr\u003e2 % - 30 min** 3 % - 15 min\u003cbr\u003e\u003cbr\u003eAll efficacy data under high load\u003cbr\u003e** = Expertly recommended dosage\/exposure time\u003cbr\u003e\u003cbr\u003eInstructions for use\u003cbr\u003ePrepare with water of at least drinking water quality. At\u003cbr\u003ethe application in the ultrasonic bath, the instructions of the\u003cbr\u003emanufacturers of ultrasonic devices must be observed. Temperatures of the\u003cbr\u003eCheck ultrasonic baths. Avoid temperatures \u0026gt;45 °C\u003cbr\u003e(protein fixation). After the treatment in the ultrasonic bath\u003cbr\u003eRinse parts thoroughly with water (see RKI recommendation)\u003cbr\u003eand dry. Instruments for cleanliness and function\u003cbr\u003echeck. Subsequent final disinfection or sterilization\u003cbr\u003edepending on the classification of the medical device. The specifications for\u003cbr\u003eProcessing of medical devices must be observed.\u003cbr\u003eThe addition of cleaning amplifiers is not permitted.\u003cbr\u003eSTAMMOPUR DR 8 is not compatible with aldehyde preparations.\u003cbr\u003ecompatible.\u003cbr\u003e* The working solution must be changed as soon as the degree of contamination\u003cbr\u003ethis requires, at the latest\u003cbr\u003eafter three days.\u003cbr\u003e\u003cbr\u003eDanger warnings\u003cbr\u003eH302 Harmful if swallowed.\u003cbr\u003eH314 Causes severe skin burns and severe eye damage.\u003cbr\u003eH317 May cause allergic skin reactions.\u003cbr\u003eH334 May cause allergy, asthma-like symptoms or difficulty breathing if inhaled.\u003cbr\u003ecause.\u003cbr\u003eH336 May cause drowsiness and dizziness.\u003cbr\u003eH361fd Suspected of affecting fertility. Suspected of causing the child in\u003cbr\u003eDamage the womb.\u003cbr\u003eH411 Toxic to aquatic organisms, with long-term effects.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eSafety Instructions\u003cbr\u003eP280 Wear protective gloves\/protective clothing\/eye protection\/face protection\u003cbr\u003eP305+P351+P338 IN CONTACT WITH EYES: Rinse gently with water for several minutes.\u003cbr\u003eRemove existing contact lenses if possible. Continue rinsing.\u003cbr\u003eP308+P313 ON EXPOSURE or if affected: Seek medical advice\/attention.\u003cbr\u003eP310 Immediately call a POISON CENTER\/Medical Service.","brand":"IDL","offers":[{"title":"1 piece","offer_id":56336770761036,"sku":"972","price":102.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/4827\/7068\/files\/62-2L_STAMMOPUR_DR_8.png?v=1766893303","url":"https:\/\/www.luminixhealth.com\/de-de\/products\/stammopur-dr-8-cleaning-and-disinfecting-agent-concentrate-2-liter","provider":"Luminix Health","version":"1.0","type":"link"}