{"product_id":"stammopur-gr-instrument-basic-cleaner-concentrate-capacityvolume-20-liters-974","title":"STAMMOPUR GR Instrument basic cleaner – concentrate, Capacity\/Volume: 2,0 liters","description":"Instruments - Disinfection\u003cbr\u003e with intensive cleaning in ultrasonic bath \u003cbr\u003e VAH-certified CE 0124\u003cbr\u003e \u003cbr\u003e At a glance\u003cbr\u003e - Concentrate\u003cbr\u003e - Developed for use in an ultrasonic bath\u003cbr\u003e - Short-term disinfection in an ultrasonic bath\u003cbr\u003e - Very high cleaning effect in the ultrasonic bath\u003cbr\u003e - Very high material compatibility\u003cbr\u003e - Aldehyde-, phenol- and chlorine-free\u003cbr\u003e - Bactericide, Batherculocide, Levurocide\u003cbr\u003e - Virucide against vaccinia, BVDV, Papova, Adeno,\u003cbr\u003e HBV, HCV, HIV, avian influenza A virus H5N1\u003cbr\u003e - Extended service life of 3 days*\u003cbr\u003e - Odourless\u003cbr\u003e \u003cbr\u003e General information\u003cbr\u003e STAMMOPUR DR 8 is designed for manual instrument disinfection\u003cbr\u003e with simultaneous intensive cleaning in an ultrasonic bath\u003cbr\u003e and for non-fixing wet storage.\u003cbr\u003e STAMMOPUR DR 8 causes short ultrasonic treatment times\u003cbr\u003e at low application concentration and is gentle on\u003cbr\u003e thus particularly highly sensitive instruments. The preparation time\u003cbr\u003e is shortened, the instruments stand faster\u003cbr\u003e available again.\u003cbr\u003e \u003cbr\u003e Material compatibility\u003cbr\u003e STAMMOPUR DR 8 has a very high material compatibility,\u003cbr\u003e is suitable for parts made of metal, glass, porcelain,\u003cbr\u003e ceramic and plastic and has a corrosion protection\u003cbr\u003e for ferrous metals. No optics, light guides and\/or glued\u003cbr\u003e Treat parts in an ultrasonic bath.\u003cbr\u003e For endoscopes and accessories the suitability recommendations are\u003cbr\u003e the companies Karl Storz GmbH and Richard Wolf GmbH\u003cbr\u003e before. The information provided by the instrument manufacturers can be obtained from\u003cbr\u003e Processing with STAMMOPUR DR 8, especially in the\u003cbr\u003e Ultrasonic bath, to be strictly observed.\u003cbr\u003e \u003cbr\u003e Dosage and application times\u003cbr\u003e Application in an ultrasonic bath\u003cbr\u003e Bactericide, Batherculocide, Levurocide\u003cbr\u003e vaccinia, BVDV, HBV, HCV, HIV, H5N1\u003cbr\u003e 2 % - 5 minutes**\u003cbr\u003e Papova 2 % - 10 minutes**\u003cbr\u003e Adeno 3 % - 15 minutes**\u003cbr\u003e Disinfection without ultrasound\u003cbr\u003e 1 % - 60 min (bactericidal, levurocidal)\u003cbr\u003e additionally effective against\u003cbr\u003e vaccinia, BVDV, Papova, HBV, HCV, HIV, H5N1\u003cbr\u003e 2 % - 30 min** 3 % - 15 min\u003cbr\u003e \u003cbr\u003e All efficacy data under high load\u003cbr\u003e ** = Expertly recommended dosage\/exposure time\u003cbr\u003e \u003cbr\u003e Instructions for use\u003cbr\u003e Prepare with water of at least drinking water quality. At\u003cbr\u003e the application in the ultrasonic bath, the instructions of the\u003cbr\u003e manufacturers of ultrasonic devices must be observed. Temperatures of the\u003cbr\u003e Check ultrasonic baths. Avoid temperatures \u0026gt;45 °C\u003cbr\u003e (protein fixation). After the treatment in the ultrasonic bath\u003cbr\u003e Rinse parts thoroughly with water (see RKI recommendation)\u003cbr\u003e and dry. Instruments for cleanliness and function\u003cbr\u003e check. Subsequent final disinfection or sterilization\u003cbr\u003e depending on the classification of the medical device. The specifications for\u003cbr\u003e Processing of medical devices must be observed.\u003cbr\u003e The addition of cleaning amplifiers is not permitted.\u003cbr\u003e STAMMOPUR DR 8 is not compatible with aldehyde preparations.\u003cbr\u003e compatible.\u003cbr\u003e * The working solution must be changed as soon as the degree of contamination\u003cbr\u003e this requires, at the latest\u003cbr\u003e after three days.\u003cbr\u003e \u003cbr\u003e Danger warnings\u003cbr\u003e H302 Harmful if swallowed.\u003cbr\u003e H314 Causes severe skin burns and severe eye damage.\u003cbr\u003e H317 May cause allergic skin reactions.\u003cbr\u003e H334 May cause allergy, asthma-like symptoms or difficulty breathing if inhaled.\u003cbr\u003e cause.\u003cbr\u003e H336 May cause drowsiness and dizziness.\u003cbr\u003e H361fd Suspected of affecting fertility. Suspected of causing the child in\u003cbr\u003e Damage the womb.\u003cbr\u003e H411 Toxic to aquatic organisms, with long-term effects.\u003cbr\u003e \u003cbr\u003e \u003cbr\u003e Safety Instructions\u003cbr\u003e P280 Wear protective gloves\/protective clothing\/eye protection\/face protection\u003cbr\u003e P305+P351+P338 IN CONTACT WITH EYES: Rinse gently with water for several minutes.\u003cbr\u003e Remove existing contact lenses if possible. Continue rinsing.\u003cbr\u003e P308+P313 ON EXPOSURE or if affected: Seek medical advice\/attention.\u003cbr\u003e P310 Immediately call a POISON CENTER\/Medical Service.","brand":"IDL","offers":[{"title":"Default Title","offer_id":57933384712524,"sku":"974","price":235.0,"currency_code":"EUR","in_stock":true}],"url":"https:\/\/www.luminixhealth.com\/en-be\/products\/stammopur-gr-instrument-basic-cleaner-concentrate-capacityvolume-20-liters-974","provider":"Luminix Health","version":"1.0","type":"link"}