{"product_id":"ultra-clear-tp-ed-20-twf-edi-30-uv-uf-tm","title":"Ultra Clear TP ED 20 TWF EDI 30 UV UF TM","description":"\u003cstrong\u003eUltra Clear TP ED 20 TWF EDI 30 UV UF TM - 2 l\/min Ultrapure water, 30L Tank, Ionpure EDI\u003c\/strong\u003e\u003cbr\u003e \u003cbr\u003e The Ultra Clear™ TP ED series comes with an electronic dispenser (ED) allowing precise and volume-controlled dispensing of your ultra pure water for flows up to 2 l\/min.\u003cbr\u003e The software is intuitive and makes dispensing easy without any delay. A printer and Modbus interface integrates the data transfer into your existing system.\u003cbr\u003e \u003cbr\u003e THE TWF EDI MODELS\u003cbr\u003e They represent the highest expansion stage of the TWF series through the use of IONPURE® EDI cell. The residual deionization of the RO permeate is at the\u003cbr\u003e highest and constant level. When fed into the tank, the quality is between 0.06 and 0.2 µS\/cm.\u003cbr\u003e With this system, we oﬀer a compact, economically aﬀordable and sustainable solution to produce two water qualities.\u003cbr\u003e \u003cbr\u003e Wall mounted or bench system with TOC monitoring producing ultrapure, pyrogen free water with a conductivity of 18.2 MOhm-cm (0.055 µS\/cm) and TOC \u0026lt; 1-5 ppb. Potable tap water fed unit, saving space by combining reverse osmosis, continuous electrodeionization, a tank and the technologies of an ultrapure water system in a single unit.\u003cbr\u003e \u003cbr\u003e The unit consists of:\u003cbr\u003e \u003cbr\u003e Pure water production:\u003cbr\u003e Reverse-osmosis \/ CEDI (Continuous Electrodeionization):\u003cbr\u003e 1 inlet solenoid valve for potable tap water\u003cbr\u003e 1 reverse osmosis (RO) pump\u003cbr\u003e 1 AMB pre-treatment module to filter and remove chlorine with activated carbon to protect the RO-module\u003cbr\u003e 1 RO-module with spiral TFC-membrane\u003cbr\u003e 1 temperature compensated permeate water conductivity sensor (SS TI, C=0.2)\u003cbr\u003e 1 conditioning module\u003cbr\u003e 1 IONPURE cell for continuous electro-deionization\u003cbr\u003e 1 temperature compensated permeate water conductivity sensor (SS TI, C=0.1)\u003cbr\u003e 1 quality dependent solenoid valve\u003cbr\u003e \u003cbr\u003e 30l polyethylene permeate tank with:\u003cbr\u003e 1 3\/4'' outlet to connect to i.e. laboratory washers\u003cbr\u003e 1 level sensor (4-20 mA)\u003cbr\u003e 1 CO2 trap and vent filter\u003cbr\u003e 1 254nm UV lamp (12 W) for disinfection\u003cbr\u003e 1 pure water dispense tap\u003cbr\u003e 1 overflow including contamination barrier\u003cbr\u003e \u003cbr\u003e Ultrapure water production:\u003cbr\u003e 1 flow turbine to recognize volume dispensed\u003cbr\u003e 1 recirculation pump, (automatic speed reduction when water is not being dispensed)\u003cbr\u003e 1 UV oxidation lamp 254\/185 nm. The UV lamp is surrounded by high quality quartz glass for TOC reduction and disinfection.\u003cbr\u003e 1 temperature compensated conductivity sensor (SS 316 TI, C=0.1, 0.1º intervals at 25ºC), monitoring TOC\u003cbr\u003e 1 polishing module MFIIID, filled with high quality synthetic activated carbon, mixed bed resin in semi-conductor quality and adsorber resin\u003cbr\u003e 1 ultra-filtration module Preventor 5000 with hollow fiber polysulphon membrane for pyrogen, RNase, DNase and colloid removal\u003cbr\u003e 1 solenoid valve for module rinsing and temperature control\u003cbr\u003e 1 temperature compensated conductivity sensor (SS 316 TI, cell constant C=0.1, 0.1º intervals at 25ºC)\u003cbr\u003e 1 temperature sensor\u003cbr\u003e 1 Electronical dispenser PVDF, dead leg free, fully integrated in the recirculation loop and electronic recognition when in standby mode\u003cbr\u003e 1 0.2µm point-of-use filter with PES membrane\u003cbr\u003e 1 volumetric ultrapure water dispenser\u003cbr\u003e 1 disinfection connection with quick fit couplers\u003cbr\u003e 1 single dose of disinfection solution\u003cbr\u003e 1 connection kit, including 2m tube\u003cbr\u003e \u003cbr\u003e Control panel:\u003cbr\u003e Graphical and programmable 7''-touch-glass panel to display:\u003cbr\u003e - flow diagram for quality parameter monitoring\u003cbr\u003e - operating pressure RO-module\u003cbr\u003e - pure water conductivity after the RO-module\u003cbr\u003e - conductivity of pure water after the IONPURE cell\u003cbr\u003e - conductivity\/resistivity of the ultrapure water\u003cbr\u003e - tank level indication in Percent\u003cbr\u003e - ultrapure water temperature (temperature compensation can be disabled according to USP)\u003cbr\u003e - conductivity reference measurement for TOC, 1-10 ppb measurement range\u003cbr\u003e - servicing and consumables exchange requirements\u003cbr\u003e - notification of system malfunction and\/or quality issues\u003cbr\u003e - settings monitoring\u003cbr\u003e - 24-hour interval setting, prolonging pump and UV-lamp lifespan\u003cbr\u003e - adjustable data backup to store conductivity, tank volume, pressure, and temperature data\u003cbr\u003e - USB connection for data analysis\u003cbr\u003e - micro-SD card for data backup (detachable)\u003cbr\u003e - language options: German, English, French, Spanish, Portuguese and Chinese\u003cbr\u003e - Managing entire unit using the control panel\u003cbr\u003e - semi-automatic, menu selectable disinfection of entire unit\u003cbr\u003e - individual setting for conductivity and temperature limits\u003cbr\u003e - automatic disposal of recirculating water when the preset temperature limit is exceeded\u003cbr\u003e - part number and consumable descriptions within the control panel\u003cbr\u003e - Simple cartridge replacement with user friendly connections\u003cbr\u003e - Generously dimensioned cartridges for longer Lifetime\u003cbr\u003e - Interface to connect POS printer or ModBus TCP\/IP Data Communication Gateway to transfer the system status information to Building Management System (BMS)\u003cbr\u003e \u003cbr\u003e The ultrapure laboratory water system is ready for use incl. the first set of modules and filters.\u003cbr\u003e \u003cbr\u003e Technical data:\u003cbr\u003e \u003cbr\u003e Pure water specifications:\u003cbr\u003e Volume flow rate:                     20 l\/h\u003cbr\u003e Conductivity:                            0.2 µS\/cm\u003cbr\u003e Tank capacity:                         30 l\u003cbr\u003e \u003cbr\u003e Ultrapure water specifications:\u003cbr\u003e Volume flow rate:                     up to 2,0 l\/min\u003cbr\u003e Conductivity:                           0.055 µS\/cm\u003cbr\u003e Resistivity:                              18.2 MOhm-cm\u003cbr\u003e TOC:                                       \u0026lt; 1-5 ppb\u003cbr\u003e Bacteria:                                 \u0026lt; 1 cfu\/ml\u003cbr\u003e Particulates \u0026gt; 0.1 µm\/ml:       \u0026lt; 1\u003cbr\u003e Endotoxins:                           \u0026lt; 0.001 EU\/ml\u003cbr\u003e DNase, RNase:                      free\u003cbr\u003e \u003cbr\u003e Feed water specifications:\u003cbr\u003e Pressure:                                0.1 - 5 bar\u003cbr\u003e Feed water flow rate:              25-30 l\/h\u003cbr\u003e Conductivity:                          \u0026lt; 1400 µS\/cm\u003cbr\u003e TOC:                                      \u0026lt; 1500 ppb\u003cbr\u003e Colloid index(SDI):                \u0026lt; 3\u003cbr\u003e Free Chlorine:                       \u0026lt; 0.1 mg\/l\u003cbr\u003e Iron:                                       \u0026lt; 0.1 mg\/l\u003cbr\u003e SiO2:                                     \u0026lt; 10 mg\/l\u003cbr\u003e CO2:                                     \u0026lt; 10 mg\/l\u003cbr\u003e Temperature:                        5 - 30ºC\u003cbr\u003e \u003cbr\u003e Mains input:                            100-240 V, 50-60 Hz\u003cbr\u003e Power consumption:                0,225 kW\u003cbr\u003e Noise pressure level:               max. 55 dB\u003cbr\u003e Electrical connection cable\u003cbr\u003e (D, GB, US):                            2 m\u003cbr\u003e Water connection                    1\/2'' or 3\/4'' female thread\u003cbr\u003e Drain tube:                               1\/4''\u003cbr\u003e \u003cbr\u003e Dimensions System:\u003cbr\u003e Width:                               340 mm\u003cbr\u003e Height:                              535 mm\u003cbr\u003e Depth:                               550 mm\u003cbr\u003e \u003cbr\u003e Dimensions 30l Tank:\u003cbr\u003e Width:                               300 mm\u003cbr\u003e Height:                              770 mm\u003cbr\u003e Depth:                               310 mm\u003cbr\u003e \u003cbr\u003e Dispatch weight:               44 kg","brand":"IDL","offers":[{"title":"1 piece","offer_id":56333462012236,"sku":"W3T276080","price":13653.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/4827\/7068\/files\/167-PK7C0096b.png?v=1766839332","url":"https:\/\/www.luminixhealth.com\/en-be\/products\/ultra-clear-tp-ed-20-twf-edi-30-uv-uf-tm","provider":"Luminix Health","version":"1.0","type":"link"}