{"product_id":"infrared-thermometer-tlc-750i-28h4-28h4","title":"Infrared thermometer TLC 750i, with factory calibration certificate, 1 unit(s)","description":"\u003cp\u003eInfrared thermometer TLC 750i, with factory calibration certificate\u003c\/p\u003e\n\u003c!-- CARLROTH_PRODUCT_DETAILS_V7 --\u003e\n\u003cdiv class=\"tabbody ProductDetailsComponent\"\u003e\n\u003cdiv class=\"row\" style=\"display:flex; flex-wrap:wrap; width:100%; max-width:100%; margin:10px 0; gap:4px;\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-6\" style=\"flex:0 0 45%; max-width:45%; box-sizing:border-box; margin:10px 0; margin-left:-2.5%; \"\u003e\n\n\n\u003c!--superDetailElements --\u003e\n\u003cdiv class=\"item\" style=\"word-wrap:break-word; overflow-wrap:anywhere; hyphens:auto; \"\u003e\n\u003cdiv class=\"details-container\"\u003e\n\n\u003cp style=\"font-size:0.95em; line-height:1.5; margin:12px 0; word-wrap:break-word; overflow-wrap:anywhere; white-space:normal; \"\u003eCombination thermometer for measuring the core temperature with fold-out contact probe or non-contact measurement with infrared sensor (type K).\u003c\/p\u003e\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"item\" style=\"word-wrap:break-word; overflow-wrap:anywhere; hyphens:auto; \"\u003e\n\u003cdiv class=\"details-container\"\u003e\n\u003cdiv class=\"paragraph-title\"\u003eApplication\u003c\/div\u003e\n\u003cp style=\"font-size:0.95em; line-height:1.5; margin:12px 0; word-wrap:break-word; overflow-wrap:anywhere; white-space:normal; \"\u003eIncoming goods inspection, transport, storage, monitoring of the cold chain.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-container\"\u003e\n\n\u003cdiv\u003e\u003cul style=\"margin:10px 0; padding-left:20px; \"\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eWith factory calibration certificate (test points: -18 and 0 °C)\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eIlluminated display for reading in the dark\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eTwo-point laser mark for indicating the actual measurement spot\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003ePenetration probe: L 100 mm x Ø 3 mm, folding\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eHACCP and DIN EN 13485 compliant\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eDust and waterproof according to IP 65\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- OtherDetailElements --\u003e\n\u003c!-- Note --\u003e\n\n\n\u003c!-- Base product name --\u003e\n\n\u003c!-- DetailElements --\u003e\n\u003cdiv class=\"item\" style=\"word-wrap:break-word; overflow-wrap:anywhere; hyphens:auto; \"\u003e\n\u003cdiv class=\"details-container\"\u003e\n\n\u003cp style=\"font-size:0.95em; line-height:1.5; margin:12px 0; word-wrap:break-word; overflow-wrap:anywhere; white-space:normal; \"\u003eDisplay rotation for easy reading from both directions. Automatic display illumination. Emissivity adjustable. With min.\/max. function.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\n\u003c!-- DeliveryText --\u003e\n\u003cdiv\u003e\n\u003cb\u003eDelivery incl.\u003c\/b\u003e factory calibration certificate and batteries.\u003c\/div\u003e\n\u003c!-- printCatalogLink --\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-md-6\" style=\"flex:0 0 55%; max-width:55%; box-sizing:border-box; margin:10px 0; margin-left:-3%; \"\u003e\n\u003cdiv class=\"product-classifications\"\u003e\n\u003cdiv class=\"headline\" style=\"font-weight:bold; font-size:1.2em; margin-bottom:10px;\"\u003eTechnical Information\u003c\/div\u003e\n\u003ctable class=\"table\" style=\"; table-layout:fixed; word-break:normal; overflow-wrap:break-word; width:100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eType\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\tTLC 750i \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eParameters\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\ttemperature \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eInfrared measuring range\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t-50 to +250 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003ePenetration probe measuring range\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t-50 to +250 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eTemperature resolution\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t0.1 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eTemperature accuracy\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\tinfrared: ±4 °C (-50 to -30 °C) ±2.5 °C (-30 to -18 °C) ±1.5 °C (-18 to 0 °C) ±1.0 °C (0 to +65 °C) ±2.0 °C (+65 to +250 °C) penetration probe: ±0.5°C (-30 to +99 °C) ±1% of the measured value (outside) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eMeasuring cycle\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\tInfrared: 0.7 s, penetration probe: 1 s \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eMeasuring distance : measuring spot ratio\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t8:1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eMeasurement spot marking\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\tyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eEmissivity\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t0,10-1,00 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eL x W x H\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t170 x 44 x 23 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t140 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003ePower supply\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t2 x 1.5 V AAA batteries \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Carl Roth","offers":[{"title":"1 pc(s) \/ 1 piece","offer_id":56130981003596,"sku":"28H4.1","price":160.3,"currency_code":"EUR","in_stock":true},{"title":"1 pc(s) \/ 6+ pieces","offer_id":56130981036364,"sku":"28H4.1","price":160.3,"currency_code":"EUR","in_stock":true},{"title":"1 pc(s) \/ 24+ pieces","offer_id":56130981069132,"sku":"28H4.1","price":160.3,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/4827\/7068\/files\/1000Wx1000H-28H4-1-01_f693fbc9-2d73-41d2-abd3-f5b77fbc5190.jpg?v=1766415194","url":"https:\/\/www.luminixhealth.com\/en-de\/products\/infrared-thermometer-tlc-750i-28h4-28h4","provider":"Luminix Health","version":"1.0","type":"link"}