{"product_id":"stammopur-db-drill-disinfecting-and-ultrasonic-cleaning-ready-to-use-capacity-977","title":"STAMMOPUR DB Drill disinfecting and ultrasonic cleaning – ready to use, Capacity","description":"Intensive cleaning and disinfection\u003cbr\u003e of medical instruments,\u003cbr\u003e Respiratory masks and work protection equipment\u003cbr\u003e VAH-certified and EXAM certificate no. 5734\/06\u003cbr\u003e \u003cbr\u003e At a glance\u003cbr\u003e - Concentrate\u003cbr\u003e - Short-term disinfection in an ultrasonic bath\u003cbr\u003e - Very high cleaning effect in the ultrasonic bath\u003cbr\u003e - Residue-free rinsing\u003cbr\u003e - Very high material compatibility\u003cbr\u003e - EXAM expert opinion for ultrasonic application\u003cbr\u003e - Free from aldehydes, chlorine and phenols\u003cbr\u003e - Bactericide, levurocide (DGHM standard methods,\u003cbr\u003e high load)\u003cbr\u003e - Virucide against: BVDV, vaccinia, HBV, HCV, HIV\u003cbr\u003e (EN 14476, high load)\u003cbr\u003e - Effective against avian influenza virus H5N1\u003cbr\u003e (EN 14476, high load)\u003cbr\u003e - Extended service life of 3 days*\u003cbr\u003e \u003cbr\u003e General information\u003cbr\u003e For cleaning and disinfection of respiratory masks,\u003cbr\u003e industrial safety equipment, medical instruments and laboratory equipment.\u003cbr\u003e STAMMOPUR 24 is specially designed for cleaning and\u003cbr\u003e disinfection in the ultrasonic bath and enables very high\u003cbr\u003e short ultrasonic treatment times at low application concentration.\u003cbr\u003e STAMMOPUR 24 is also suitable for disinfection after\u003cbr\u003e after cleaning.\u003cbr\u003e Material compatibility\u003cbr\u003e STAMMOPUR 24 has a very high material compatibility\u003cbr\u003e and is suitable for parts made of metal (also light metal), glass,\u003cbr\u003e Porcelain, plastic and rubber.\u003cbr\u003e The material compatibility of STAMMOPUR 24 in the ultrasonic bath\u003cbr\u003e on breathing connections from MSA AUER GmbH is\u003cbr\u003e by an expert opinion of the EXAM specialist centre for respiratory protection\u003cbr\u003e confirmed. During the reprocessing of respirator masks and\u003cbr\u003e their accessories as well as on instruments, the instructions of\u003cbr\u003e manufacturer, especially in connection with ultrasound, strictly to\u003cbr\u003e note.\u003cbr\u003e \u003cbr\u003e Dosage and application times\u003cbr\u003e Application in an ultrasonic bath\u003cbr\u003e Bactericide, levurocide,\u003cbr\u003e virucidal against: BVDV, vaccinia, HBV, HCV, HIV, H5N1\u003cbr\u003e Intensive cleaning with disinfection\u003cbr\u003e 1 % - 15 min** 2 % - 5 min**\u003cbr\u003e Disinfection without ultrasound\u003cbr\u003e 1 % - 60 min (bactericidal, levurocidal)\u003cbr\u003e additionally effective against\u003cbr\u003e BVDV, vaccinia, HBV, HCV, HIV, H5N1\u003cbr\u003e 2 % - 30 min** 3 % - 15 min\u003cbr\u003e All efficacy data under high load\u003cbr\u003e ** = Expertly recommended dosage\/exposure time\u003cbr\u003e \u003cbr\u003e Instructions for use\u003cbr\u003e Prepare with water of at least drinking water quality. At\u003cbr\u003e the complete wetting of the cleaning material must be ensured.\u003cbr\u003e Insert the hollow body so that the air from the cavities\u003cbr\u003e completely escaped.\u003cbr\u003e When using in an ultrasonic bath, the instructions of the\u003cbr\u003e ultrasonic device manufacturers must be strictly observed. Not with\u003cbr\u003e warm water, do not heat up additionally.\u003cbr\u003e Check the temperature of the ultrasonic bath, temperatures\u003cbr\u003e \u0026gt;45 °C should be avoided.\u003cbr\u003e After treatment, thoroughly clean parts with water (according to RKI recommendation)\u003cbr\u003e rinse and dry. The specifications for preparation\u003cbr\u003e of medical devices must be observed. The addition of\u003cbr\u003e Cleaning amplifiers are not permitted. STAMMOPUR 24 is\u003cbr\u003e not compatible with aldehydic preparations. Before the\u003cbr\u003e Change from STAMMOPUR 23 or another\u003cbr\u003e aldehydic disinfectant on STAMMOPUR 24 are\u003cbr\u003e carefully rinse the instruments\/materials with water.\u003cbr\u003e * The working solution should be used for visible soiling\u003cbr\u003e immediately, otherwise after 3 days at the latest.\u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e Danger warnings\u003cbr\u003e H302 Harmful if swallowed.\u003cbr\u003e H314 Causes severe skin burns and severe eye damage.\u003cbr\u003e H317 May cause allergic skin reactions.\u003cbr\u003e H334 May cause allergy, asthma-like symptoms or difficulty breathing if inhaled.\u003cbr\u003e cause.\u003cbr\u003e H336 May cause drowsiness and dizziness.\u003cbr\u003e H361fd Suspected of affecting fertility. Suspected of causing the child in\u003cbr\u003e Damage the womb.\u003cbr\u003e H411 Toxic to aquatic organisms, with long-term effects.\u003cbr\u003e \u003cbr\u003e Safety Instructions\u003cbr\u003e P280 Wear protective gloves\/protective clothing\/eye protection\/face protection\u003cbr\u003e P305+P351+P338 IN CONTACT WITH EYES: Rinse gently with water for several minutes.\u003cbr\u003e Remove existing contact lenses if possible. Continue rinsing.\u003cbr\u003e P308+P313 ON EXPOSURE or if affected: Seek medical advice\/attention.\u003cbr\u003e P310 Call TOXIC INFORMATION CENTRE\/MEDICINE immediately.","brand":"IDL","offers":[{"title":"Default Title","offer_id":57933385924940,"sku":"977","price":102.0,"currency_code":"EUR","in_stock":true}],"url":"https:\/\/www.luminixhealth.com\/en-fr\/products\/stammopur-db-drill-disinfecting-and-ultrasonic-cleaning-ready-to-use-capacity-977","provider":"Luminix Health","version":"1.0","type":"link"}