Rack 14x5-7 ml D13 mm Vac/Sar is a centrifuge accessory rack designed to accommodate fourteen 5–7 ml tubes of 13 mm diameter, suitable for Vacutainer and Sarstedt-style vessels. Delivered as a pack of two pieces, the rack provides secure tube positioning for centrifugation workflows in clinical, research and industrial laboratories. Net weight of the set is 0,56 kg; packaging measures approximately 0,16 m width, 0,17 m depth and 0,085 m height with a volume of 0,002 m³. Manufactured by Ohaus, it belongs to the centrifuge accessories category and is intended for use with compatible centrifuge systems accepting the 5–7 ml / 13 mm tube format. The configuration supports stable placement of blood-collection or similar tubes throughout spin cycles, assisting laboratories in maintaining orderly sample handling and efficient throughput. With two racks per pack, users gain flexibility for parallel runs or spare capacity, making this accessory a practical component for routine sample preparation and separation tasks involving smaller-volume tubes.

This article is part of Rotor adapters & accessories, in Centrifuges.

Key features

  • Pack size: 2 pc(s)
  • Capacity: 14 × 5–7 ml tubes
  • Tube diameter: 13 mm
  • Tube compatibility: Vac/Sar
  • Product type: Centrifuge Accessories

Recently viewed

You may also like

Questions about Rack 14x5-7ml D13mm Vac/Sar 2/pk

What is this article?

Rack 14x5-7ml D13mm Vac/Sar 2/pk is the article on this page. Luminix Health distributes Ohaus for laboratory use. It sits in Rotor adapters & accessories, inside Centrifuges, in Lab instruments.

An adapter lets a rotor spun for large tubes accept smaller ones. The adapter has to be the one for that rotor, and the tubes have to be supported at the shoulder the adapter was designed for. A stack of the wrong inserts is an unbalanced load.

A centrifuge separates by density. The rotor spins the sample and the force is reported as a multiple of gravity, not as a raw speed, because the same revolutions per minute are a different force at a different radius. A microcentrifuge takes small tubes. A benchtop or floor model takes larger rotors. The tube, the adapter and the rotor have to be the combination the manufacturer rated. An unbalanced load is how centrifuges fail. Measurement of the related quantities sits with the BIPM.

Which category should I open next?
What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.