{"product_id":"benchtop-ph-meters-1xx4-1xx4","title":"Benchtop pH meters, SevenDirect(TM) SD20 LowVol kit, 1 unit(s)","description":"\u003cp\u003eBenchtop pH meters, SevenDirect(TM) SD\u003csub\u003e20\u003c\/sub\u003e LowVol kit, incl. InLab® Micro Pro-ISM®, buffer solutions (pH 4.01, 7.00, 9.21 and 10.00, 2 x 20 ml of each), electrode holder and protective cover.\u003c\/p\u003e\n\u003c!-- CARLROTH_PRODUCT_DETAILS_V7 --\u003e\n\u003cdiv class=\"tabbody ProductDetailsComponent\"\u003e\n\u003cdiv class=\"row\" style=\"display:flex; flex-wrap:wrap; width:100%; max-width:100%; margin:10px 0; gap:4px;\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-6\" style=\"flex:0 0 45%; max-width:45%; box-sizing:border-box; margin:10px 0; margin-left:-2.5%; \"\u003e\n\n\n\u003c!--superDetailElements --\u003e\n\u003cdiv class=\"item\" style=\"word-wrap:break-word; overflow-wrap:anywhere; hyphens:auto; \"\u003e\n\u003cdiv class=\"details-container\"\u003e\n\n\u003cp style=\"font-size:0.95em; line-height:1.5; margin:12px 0; word-wrap:break-word; overflow-wrap:anywhere; white-space:normal; \"\u003eFor determining pH\/Redox.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-container\"\u003e\n\n\u003cdiv\u003e\u003cul style=\"margin:10px 0; padding-left:20px; \"\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eLarge colour touchscreen (7″) for straightforward data input and direct measurements.\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eSimple and intuitive operation. On-screen instructions provide step-by-step guidance through the programs (e.g. sensor calibration). \u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eScreen display can be adjusted for specific requirements. Full-screen mode displays all information, while the details screen only shows the most important measurement information with large digits.\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eCalibration can be performed with predefined and user-specific buffers and buffer groups. Calibration memory with optional sensor lock setting available. Quality of the most recent sensor calibration shown directly via pH sensor symbol. Verification mode enables checking of the current sensor status.\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eElectrode arm can be operated easily with one hand. Simple and safe electrode handling via specific positions for cleaning and storage. Precise positioning via vertical and horizontal movements.\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eTraceable documentation. With each measurement, data such as the timestamp or sample and sensor ID is saved and automatically printed or exported.\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eTwo-level user management (administrator, operator) prevents unwanted changes to device settings.\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eInternal measurement data memory: save by pressing a key or with time-controlled, measuring intervals.\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eIntelligent Sensor Management (ISM\u003csup\u003e®\u003c\/sup\u003e) for automatic recognition of ISM\u003csup\u003e®\u003c\/sup\u003e sensors and reading in calibration data.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- OtherDetailElements --\u003e\n\u003c!-- Note --\u003e\n\n\n\u003c!-- Base product name --\u003e\n\n\u003c!-- DetailElements --\u003e\n\u003cdiv class=\"item\" style=\"word-wrap:break-word; overflow-wrap:anywhere; hyphens:auto; \"\u003e\n\u003cdiv class=\"details-container\"\u003e\n\n\u003cp style=\"font-size:0.95em; line-height:1.5; margin:12px 0; word-wrap:break-word; overflow-wrap:anywhere; white-space:normal; \"\u003eFor measurements in small or narrow vessels (such as test tubes, vials and cells) or for small sample volumes.InLab\u003csup\u003e®\u003c\/sup\u003e Micro Pro-ISM\u003csup\u003e®\u003c\/sup\u003e pH single-rod measuring cell with integrated temperature gauge and small shaft diameter.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\n\u003c!-- DeliveryText --\u003e\n\u003cdiv\u003e\n\u003cb\u003eDelivery incl.\u003c\/b\u003e InLab\u003csup\u003e®\u003c\/sup\u003e Micro Pro-ISM\u003csup\u003e®\u003c\/sup\u003e, buffer solutions (pH 4.01, 7.00, 9.21 and 10.00, 2 x 20 ml of each), electrode holder and protective cover.\u003c\/div\u003e\n\u003c!-- printCatalogLink --\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-md-6\" style=\"flex:0 0 55%; max-width:55%; box-sizing:border-box; margin:10px 0; margin-left:-3%; \"\u003e\n\u003cdiv class=\"product-classifications\"\u003e\n\u003cdiv class=\"headline\" style=\"font-weight:bold; font-size:1.2em; margin-bottom:10px;\"\u003eTechnical Information\u003c\/div\u003e\n\u003ctable class=\"table\" style=\"; table-layout:fixed; word-break:normal; overflow-wrap:break-word; width:100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eType\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\tSD20 LowVol kit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eSensor\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\tInLab\u003csup\u003e®\u003c\/sup\u003e Micro Pro-ISM\u003csup\u003e®\u003c\/sup\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eParameters\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\tpH redox temperature \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003epH measuring range\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t-2 to +20 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003epH resolution\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t0,001 \/ 0,01 \/ 0,1 pH \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003epH accuracy\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t±0.002 pH \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eVoltage measuring range\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t-2000 to +2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eVoltage resolution\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t0,1 \/ 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eVoltage accuracy\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t±0,2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eTemperature measuring range\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t-30 to +130 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eTemperature resolution\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t0.1 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eTemperature accuracy\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t±0.1 °C (0.0 to 100.0 °C) ±0.3 °C (outside) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eTemperature sensor\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\tNTC 30 kΩ, pt 1000 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eCalibration points\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t1\/2\/3\/4\/5 (pH) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eCalibration memory\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\tcurrent calibration (incl. date and time) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eData memory\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t2000 datasets \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003ePort\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\tUSB-A (USB stick, printer, barcode reader), USB-B (PC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eISM Technology\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\tyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eIP rating\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t54 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eConnection\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\tBNC (pH), Cinch (°C) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eL x W x H\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t205 x 195 x 65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003ePower supply\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\tmains adapter \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eMains connection\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t100-240 V, 50\/60 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"margin-top:1.5rem;\"\u003e\n  \u003ca href=\"https:\/\/www.carlroth.com\/medias\/BA-PRO-1909232-EN.pdf?context=bWFzdGVyfGluc3RydWN0aW9uc3wyMzUyNzgzfGFwcGxpY2F0aW9uL3BkZnxhRGd3TDJnMVlTODVNVEk1TVRNeU5UZzVNRGcyTDBKQlgxQlNUMTh4T1RBNU1qTXlYMFZPTG5Ca1pnfDI4MGYyMDg0ZGM1NzA1NjI5NTliMDg4Nzc0N2ZhODM0M2I2ZThlYmE5Y2U4MDcwMDdlZmM3MDI3YjU4NWM1YzI\" target=\"_blank\" rel=\"noopener noreferrer\" download style=\"display:inline-flex; align-items:center; gap:.65rem; text-decoration:none; color:#000; font-weight:600; font-size:1rem;\"\u003e\n    \u003csvg style=\"width:1.65rem;height:1.65rem;color:#dc2626;flex-shrink:0;\" viewbox=\"0 0 384 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" aria-hidden=\"true\"\u003e\n      \u003cpath d=\"M64 0C28.7 0 0 28.7 0 64V448c0 35.3 28.7 64 64 64H320c35.3 0 64-28.7 64-64V160H256c-17.7 0-32-14.3-32-32V0H64z\" fill=\"#ffffff\" stroke=\"currentColor\" stroke-width=\"32\"\u003e\u003c\/path\u003e\n      \u003cpath d=\"M256 0V128H384L256 0z\" fill=\"currentColor\"\u003e\u003c\/path\u003e\n      \u003ctext x=\"192\" y=\"380\" font-family=\"Arial, Helvetica, sans-serif\" font-size=\"110\" font-weight=\"bold\" fill=\"currentColor\" text-anchor=\"middle\"\u003ePDF\u003c\/text\u003e\n    \u003c\/svg\u003e\n    Technical Documentation (PDF)\n  \u003c\/a\u003e\n\u003c\/div\u003e","brand":"Carl Roth","offers":[{"title":"1 pc(s) \/ 1 piece","offer_id":56125789569356,"sku":"1XX4.1","price":1875.0,"currency_code":"EUR","in_stock":true},{"title":"1 pc(s) \/ 6+ pieces","offer_id":56125789602124,"sku":"1XX4.1","price":1875.0,"currency_code":"EUR","in_stock":true},{"title":"1 pc(s) \/ 24+ pieces","offer_id":56125789634892,"sku":"1XX4.1","price":1875.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/4827\/7068\/files\/1XX4-01-1000Wx1000H_9b016777-a331-499a-be95-686bcb29f221.jpg?v=1766405661","url":"https:\/\/www.luminixhealth.com\/en-nl\/products\/benchtop-ph-meters-1xx4-1xx4","provider":"Luminix Health","version":"1.0","type":"link"}