{"product_id":"dispensette-s-ta-with-rdv-ecx4-ecx4","title":"Dispensette® S TA, with RDV, Tantalum, volumen 1-10ml, 1 unit(s)","description":"\u003cp\u003eDispensette® S TA, with RDV, Tantalum, volumen 1-10ml\u003c\/p\u003e\n\u003c!-- CARLROTH_PRODUCT_DETAILS_V7 --\u003e\n\u003cdiv class=\"tabbody ProductDetailsComponent\"\u003e\n\u003cdiv class=\"row\" style=\"display:flex; flex-wrap:wrap; width:100%; max-width:100%; margin:10px 0; gap:4px;\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-6\" style=\"flex:0 0 45%; max-width:45%; box-sizing:border-box; margin:10px 0; margin-left:-2.5%; \"\u003e\n\n\n\u003c!--superDetailElements --\u003e\n\u003cdiv class=\"item\" style=\"word-wrap:break-word; overflow-wrap:anywhere; hyphens:auto; \"\u003e\n\u003cdiv class=\"details-container\"\u003e\n\n\u003cp style=\"font-size:0.95em; line-height:1.5; margin:12px 0; word-wrap:break-word; overflow-wrap:anywhere; white-space:normal; \"\u003e\u003cb\u003eRange of application:\u003c\/b\u003e for accurate dispensing of high purity media in trace analysis. Dispensing of metal traces, usually in the low ppb range, or even in the ppt range, depending on the application. The established cleaning process for use in trace analysis is explained in the operating instructions. Can be used as a dispenser for hydrofluoric acid with a platinum-iridium valve spring.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-container\"\u003e\n\u003cdiv class=\"\"\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cul style=\"margin:10px 0; padding-left:20px; \"\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eDepending on requirements, the spring material is made of platinum-iridium or tantalum\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eValves without additional ring seals for easier cleaning\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eDispensing plunger with snug fitting seal\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eComplete dispensing unit easily replaceable when worn\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eReliable volume control via internal toothed rack\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eRotates through 360°, valve block with GL 45 thread\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eDischarge tube with swivel-mounted screw cap for protection against media contact\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eTelescopic suction tube adjustable to different bottle sizes\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eDE-M approved\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eSuitable for calibration in conjunction with measuring instrument inspection according to ISO 9011 and GLP\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eChange to factory calibration is shown\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eMicrofilter can be connected for sterile dispensing\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"item\" style=\"word-wrap:break-word; overflow-wrap:anywhere; hyphens:auto; \"\u003e\n\u003cdiv class=\"details-container\"\u003e\n\n\u003cp style=\"font-size:0.95em; line-height:1.5; margin:12px 0; word-wrap:break-word; overflow-wrap:anywhere; white-space:normal; \"\u003e\u003cb\u003eMaterials in contact with media \u003c\/b\u003eHigh-purity plastics (PTFE, ETFE, PCTFE, FEP and PFA), sapphire valves, platinum-iridium or tantalum spring material.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"item\" style=\"word-wrap:break-word; overflow-wrap:anywhere; hyphens:auto; \"\u003e\n\u003cdiv class=\"details-container\"\u003e\n\n\u003cp style=\"font-size:0.95em; line-height:1.5; margin:12px 0; word-wrap:break-word; overflow-wrap:anywhere; white-space:normal; \"\u003e\u003cb\u003eLimits of use \u003c\/b\u003eMax. vapour pressure 600 mbar; max. viscosity 500 mm²\/s; max. temperature +40 °C; max. density 3.8 g\/cm³.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- OtherDetailElements --\u003e\n\u003c!-- Note --\u003e\n\n\n\u003c!-- Base product name --\u003e\n\n\u003c!-- DetailElements --\u003e\n\u003cdiv class=\"item\" style=\"word-wrap:break-word; overflow-wrap:anywhere; hyphens:auto; \"\u003e\n\u003cdiv class=\"details-container\"\u003e\n\n\u003cp style=\"font-size:0.95em; line-height:1.5; margin:12px 0; word-wrap:break-word; overflow-wrap:anywhere; white-space:normal; \"\u003eDischarge tube with recirculation valve prevents reagent loss and allows quick, bubble-free ventilation.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\n\u003c!-- DeliveryText --\u003e\n\u003cdiv\u003e\n\u003cb\u003eDelivery incl.\u003c\/b\u003e quality certificate, recirculation tune, telescopic filling tube, valve mounting tool and thread adapter.\u003c\/div\u003e\n\u003c!-- printCatalogLink --\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-md-6\" style=\"flex:0 0 55%; max-width:55%; box-sizing:border-box; margin:10px 0; margin-left:-3%; \"\u003e\n\u003cdiv class=\"product-classifications\"\u003e\n\u003cdiv class=\"headline\" style=\"font-weight:bold; font-size:1.2em; margin-bottom:10px;\"\u003eTechnical Information\u003c\/div\u003e\n\u003ctable class=\"table\" style=\"; table-layout:fixed; word-break:normal; overflow-wrap:break-word; width:100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eVersion\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\tTantalum, with RDV \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eVolume\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t1-10 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eGraduation\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t0,2 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eCorrectness\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t±50 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eVariation coefficient\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t±10 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t+15 - +40 °C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eAdapter\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\tGL 28\/ S 28 (ETFE), GL 32 (ETFE), GL38 (ETFE), S 40 (PTFE) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eSuction tube length\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t240 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv style=\"margin-top:1.5rem;\"\u003e\n  \u003ca href=\"https:\/\/www.carlroth.com\/medias\/BA-PRO-326606-EN.pdf?context=bWFzdGVyfGluc3RydWN0aW9uc3wxNDQ2MDMxfGFwcGxpY2F0aW9uL3BkZnxhVzV6ZEhKMVkzUnBiMjV6TDJoaE55OW9Zakl2T0RrNU1UQTBPRFUyTkRjMk5pNXdaR1l8MzY2MDVkNGFkOWUyNTM0YWZmNjdjOGJiODQ3NDk0NmUxMmYxMzE1ODI0ODYyMDQzOTFiYWFmOTdiZGY5NzJlMw\" target=\"_blank\" rel=\"noopener noreferrer\" download style=\"display:inline-flex; align-items:center; gap:.65rem; text-decoration:none; color:#000; font-weight:600; font-size:1rem;\"\u003e\n    \u003csvg style=\"width:1.65rem;height:1.65rem;color:#dc2626;flex-shrink:0;\" viewbox=\"0 0 384 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" aria-hidden=\"true\"\u003e\n      \u003cpath d=\"M64 0C28.7 0 0 28.7 0 64V448c0 35.3 28.7 64 64 64H320c35.3 0 64-28.7 64-64V160H256c-17.7 0-32-14.3-32-32V0H64z\" fill=\"#ffffff\" stroke=\"currentColor\" stroke-width=\"32\"\u003e\u003c\/path\u003e\n      \u003cpath d=\"M256 0V128H384L256 0z\" fill=\"currentColor\"\u003e\u003c\/path\u003e\n      \u003ctext x=\"192\" y=\"380\" font-family=\"Arial, Helvetica, sans-serif\" font-size=\"110\" font-weight=\"bold\" fill=\"currentColor\" text-anchor=\"middle\"\u003ePDF\u003c\/text\u003e\n    \u003c\/svg\u003e\n    Technical Documentation (PDF)\n  \u003c\/a\u003e\n\u003c\/div\u003e","brand":"Carl Roth","offers":[{"title":"1 pc(s) \/ 1 piece","offer_id":56181375435084,"sku":"ECX4.1","price":965.35,"currency_code":"EUR","in_stock":true},{"title":"1 pc(s) \/ 6+ pieces","offer_id":56181375467852,"sku":"ECX4.1","price":965.35,"currency_code":"EUR","in_stock":true},{"title":"1 pc(s) \/ 24+ pieces","offer_id":56181375500620,"sku":"ECX4.1","price":965.35,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/4827\/7068\/files\/1000Wx1000H-ECX4-1-01_da2b4910-67d4-404f-8006-7d6b1048ed84.jpg?v=1766448590","url":"https:\/\/www.luminixhealth.com\/fr-be\/products\/dispensette-s-ta-with-rdv-ecx4-ecx4","provider":"Luminix Health","version":"1.0","type":"link"}