{"product_id":"stericlin-type-5-indicator-strips-hxe9-hxe9","title":"stericlin® type 5 indicator strips, (STEAM), L 80 x W 30 mm, 500 unit(s)","description":"\u003cp\u003estericlin® type 5 indicator strips, (STEAM), L 80 x W 30 mm\u003c\/p\u003e\n\u003c!-- CARLROTH_PRODUCT_DETAILS_V7 --\u003e\n\u003cdiv class=\"tabbody ProductDetailsComponent\"\u003e\n\u003cdiv class=\"row\" style=\"display:flex; flex-wrap:wrap; width:100%; max-width:100%; margin:10px 0; gap:4px;\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-6\" style=\"flex:0 0 45%; max-width:45%; box-sizing:border-box; margin:10px 0; margin-left:-2.5%; \"\u003e\n\u003cdiv\u003eAutoclavable: yes.\u003c\/div\u003e\n\n\u003c!--superDetailElements --\u003e\n\u003cdiv class=\"item\" style=\"word-wrap:break-word; overflow-wrap:anywhere; hyphens:auto; \"\u003e\n\u003cdiv class=\"details-container\"\u003e\n\n\u003cp style=\"font-size:0.95em; line-height:1.5; margin:12px 0; word-wrap:break-word; overflow-wrap:anywhere; white-space:normal; \"\u003e\u003cb\u003eAbsorptive indicators for package monitoring according to DIN EN ISO 11140-1\u003c\/b\u003e. Review of the sterilisation process for sufficient influence from the vapour (vapour and temperature) in the interior of packaging or in other selected areas. Free from heavy metals and toxic substances.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-container\"\u003e\n\u003cdiv class=\"\"\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cul style=\"margin:10px 0; padding-left:20px; \"\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003ePlace in the desired areas of the load (in transparent packaging, wrapping materials, containers, etc.)\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eCarry out the sterilisation program (121 °C\/134 °C)\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eRemove the indicator strips\u003c\/li\u003e\n\u003cli style=\"margin:6px 0; word-wrap:break-word; overflow-wrap:anywhere; \"\u003eReview the result: In the event of sufficient influence from vapour, the indicator will change colour from blue to pink. An incomplete colour change indicates a malfunction of the steriliser. Following a successful colour conversion, the colour hue of the indicator will no longer change. This ensures complete reliability of documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- OtherDetailElements --\u003e\n\u003c!-- Note --\u003e\n\n\n\u003c!-- Base product name --\u003e\n\n\u003c!-- DetailElements --\u003e\n\n\n\u003c!-- DeliveryText --\u003e\n\n\u003c!-- printCatalogLink --\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-md-6\" style=\"flex:0 0 55%; max-width:55%; box-sizing:border-box; margin:10px 0; margin-left:-3%; \"\u003e\n\u003cdiv class=\"product-classifications\"\u003e\n\u003cdiv class=\"headline\" style=\"font-weight:bold; font-size:1.2em; margin-bottom:10px;\"\u003eTechnical Information\u003c\/div\u003e\n\u003ctable class=\"table\" style=\"; table-layout:fixed; word-break:normal; overflow-wrap:break-word; width:100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eStandards\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\tDIN EN ISO 11140‑1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eW x L\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t30 x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attrib\" style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-weight:bold; font-size:1em; white-space:normal; overflow-wrap:break-word; hyphens:auto; word-break:normal; \"\u003eManufacturer no.\u003c\/td\u003e\n\u003ctd style=\"padding:8px 6px; vertical-align:top; box-sizing:border-box; font-size:0.92em; white-space:normal; word-break:normal; overflow-wrap:break-word; hyphens:auto; \"\u003e\n\t\t\t\t\t\t\t\t\t3FSKS646102 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Carl Roth","offers":[{"title":"500 pc(s) \/ 1 piece","offer_id":56181921874252,"sku":"HXE9.1","price":66.1,"currency_code":"EUR","in_stock":true},{"title":"500 pc(s) \/ 6+ pieces","offer_id":56181921907020,"sku":"HXE9.1","price":62.8,"currency_code":"EUR","in_stock":true},{"title":"500 pc(s) \/ 24+ pieces","offer_id":56181921939788,"sku":"HXE9.1","price":59.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/4827\/7068\/files\/HXE9-1000Wx1000H_f6fe26b1-f7fb-4dfc-aeae-e4412cbe15b7.jpg?v=1766479126","url":"https:\/\/www.luminixhealth.com\/fr-fr\/products\/stericlin-type-5-indicator-strips-hxe9-hxe9","provider":"Luminix Health","version":"1.0","type":"link"}