MT media temperature control with flexible temperature sensor, control via temperature in liquids or media
RM module - rapid cooling for liquids in open vessels , direct jacket cooling with demineralised water incl. MT media temperature control and sterile ventilation
RG module - rapid cooling for liquids in open and pressure-tight sealed vessels incl. RM module, additionally with sterile support pressure and radial blower for steam circulation, external compressed air connection required
VF module - fractionated pre-vacuum for solid and porous materials that are difficult to deaerate, especially hollow bodies and waste in bags, incl. programme for simple pre-vacuum
VT module - vacuum drying incl. VF module Post-drying with vacuum, double jacket steam-heated, for all solid and porous materials including sterile ventilation, recommended drying time 15 to 60 min
FA module - exhaust air filtration with condensate sterilisation recommended for all contaminated sterile goods from protection class/safety level L1 (S1), from L2 (S2) required by supervisory authorities
GLP batch printer, integrated in the unit for direct documentation of chamber temperature, media temperature and chamber pressure
GMP batch printer, integrated in the unit for independent documentation of chamber temperature, media temperature and chamber pressure as well as separate process documentation via dual sensors, incl. calibration certificates according to ISO 9000, GMP compliant
Sterileventilation Sterile chamber ventilation at the end of the sterilisation process
Available equipment options
Autoclave cladding made of stainless steel, finely ground, instead of powder coating
Validation feed-through 6-fold, for up to 6 temperature sensors Pt 100, standard-compliant connections
Set of castors with parking brake, for mobile installation of floor-standing units, 1 set = 4 pieces
51902900
VARIOKLAV BlueLine 100 S
1 piece
€20.500,00
Store locator
Heading
Add address
Heading
Add address
Heading
Add address
VARIOKLAV BlueLine 100 S
Pack Size
Menge
VARIOKLAV Steam Steriliser BlueLine 100 S
Free-standing unit - vertical installation
Usable space 100 litres
separate steam generator
integrated ADI exhaust steam condenser
powder-coated stainless steel cladding
Available module options
MT media temperature control with flexible temperature sensor, control via temperature in liquids or media
RM module - rapid cooling for liquids in open vessels , direct jacket cooling with demineralised water incl. MT media temperature control and sterile ventilation
RG module - rapid cooling for liquids in open and pressure-tight sealed vessels incl. RM module, additionally with sterile support pressure and radial blower for steam circulation, external compressed air connection required
VF module - fractionated pre-vacuum for solid and porous materials that are difficult to deaerate, especially hollow bodies and waste in bags, incl. programme for simple pre-vacuum
VT module - vacuum drying incl. VF module Post-drying with vacuum, double jacket steam-heated, for all solid and porous materials including sterile ventilation, recommended drying time 15 to 60 min
FA module - exhaust air filtration with condensate sterilisation recommended for all contaminated sterile goods from protection class/safety level L1 (S1), from L2 (S2) required by supervisory authorities
GLP batch printer, integrated in the unit for direct documentation of chamber temperature, media temperature and chamber pressure
GMP batch printer, integrated in the unit for independent documentation of chamber temperature, media temperature and chamber pressure as well as separate process documentation via dual sensors, incl. calibration certificates according to ISO 9000, GMP compliant
Sterileventilation Sterile chamber ventilation at the end of the sterilisation process
Available equipment options
Autoclave cladding made of stainless steel, finely ground, instead of powder coating
Validation feed-through 6-fold, for up to 6 temperature sensors Pt 100, standard-compliant connections
Set of castors with parking brake, for mobile installation of floor-standing units, 1 set = 4 pieces