(Ultra)pure water system, OmniaTap UV/UF 20 l/h, with 10 l tank, 1 unit(s)

SKU: 38E8.1

Volume: 1 pc(s)
Value Packs: 1 piece
Preis:
Sonderpreis€9.200,95

Beschreibung

(Ultra)pure water system, OmniaTap UV/UF 20 l/h, with 10 l tank, incl. OmniaTap ultrapure water system, 10 l storage tank, pretreatment and ultrapure water cartridge, UV lamp, ultrafiltration module, sterile filter, 3 x PE hoses and R 3/4 water connection adapter. Contains LITHIUM-ION CELLS. Not subject to labelling according to ADR SV188., UN-Nr. 3091

Treatment system for producing both pure and ultrapure water. Connectible directly to the mains water supply. With the flexible dispenser, ultrapure water of the category ASTM type I is extracted. The water is drawn at the touch of a button using the dispenser's digital control. A tank with recirculation keeps the quality permanently at ASTM Type II. These OmniaTap devices are optionally available with an integrated 10 l pure water storage tank or without a storage tank. Accessories for the OmniaTap devices without a storage tank include separately connectable 30 l or 60 l storage tanks. An optionally available pump station can be used to supply downstream devices, such as autoclaves or dishwashers, directly with pure water (ASTM Type II) from the pure water storage tank. Note: the 30 l or 60 l storage tank is not included in the scope of delivery and must be ordered separately for devices without a storage tank as an accessory required for operation. This appliance series cannot be operated without a connected pure water storage tank.

  • TapWater set - direct connection to drinking water
  • OptiFill dispenser as standard, one-handed operation
  • Dispenser has a swivel range of up to 170°
  • Two language settings available: DE, EN
  • Ultrapure water withdrawal at the touch of a button
  • Space-saving mounting on a laboratory bench or optionally on a wall
  • Optionally available with integrated 10 l storage tank or without storage tank; separate 30 l or 60 l storage tanks are available as accessories
  • Tank volume display in percent
  • Simple and cost-effective filter replacement
  • RS 232 interface
  • Leak sensor as standard
  • Ready to use, ready to connect, incl. filter cartridges
Feed water requirements: drinking water acc. to DIN 2000
Feed water temperature (°C) +2-35
Feed water pressure (bar) 0.5-6
Manganese, aluminium and iron content (ppm) <0.05
Free chlorine (ppm) <4
Silt density index (SDI) Max. 3
pH range 4-11
Note: endotoxin concentration and TOC value depend on the quality of the feed water. The 0.2 µm sterile filter capsule is needed to meet the requirements for particle and bacteria content.

Typical applications: cell culture media, molecular biology and microbiology.

Delivery incl. OmniaTap UV/UF ultrapure water system with integrated 10 l tank, sterile tank overflow and breather filter, pretreatment cartridge (RO cartridge), ultrapure water cartridge, UV lamp, ultrafiltration module (UF), sterile filter capsule 0.2 μm, 3 x PE hoses Ø 8 mm, L 2.5 m, water connection adapter R 3/4″.
Technical Information
Type OmniaTap UV/UF 20 l/h with 10 l storage tank 
Vol. 10 l
Conductivity of high-purity water, type I 0.055 µS/cm
Conductivity of pure water, type II 0.067-0.1 µS/cm
Resistance of high-purity water, type I 18.2 MΩ·cm
Resistance of pure water, type II 10-15 MΩ·cm
Withdrawal capacity of high-purity water, type I 1.6 l/min
Withdrawal capacity of pure water, type II 20 l/h
Bacteria content of high-purity water, type I <0,1 KbE/ml 
Endotoxin content of high-purity water, type I <0.001 EU/ml
TOC value of high-purity water, type I 1-5 ppb
Particle content of high-purity water, type I <1 particle per ml (particle size >0.2 μm) 
Port RS-232 
Width 390 mm
Depth 615 mm
Height 720 mm
Weight 21.2 kg
Min. operating pressure 2 bar
Max. operating pressure 6 bar
Ambient temperature 2-35 °C
Connection R 3/4″ 
Mains connection 100-240 V, 50/60 Hz 