Description
Density hydrometer 0,750–0,800 g/cm³ is a laboratory glass instrument for determining liquid density within a defined low-density interval. Built to DIN 12791 and identified as type M50-075, it covers the measuring range 0,750–0,800 g/cm³ with a fine scale division of 0,001 g/cm³. The hydrometer is supplied without an integrated thermometer and has an overall length of 260 mm. It is calibratable (eichfähig), supporting use where verified density readings are required in quality control and routine laboratory work. This model from manufacturer Witeg is intended for density checks on lighter liquids and process samples in research, industrial, and analytical settings. Offered as a single piece with a net weight of 0,049 kg, the instrument combines a clear g/cm³ scale with standardized construction for consistent immersion readings in suitable measuring cylinders. The compact 260 mm body suits everyday bench use while remaining aligned with established hydrometer practice under DIN 12791 for density determination in g/cm³.
This article is part of Hydrometers, in Density & viscosity measurement.
Key features
- Pack size: 1 pc
- Measuring range: 0,750–0,800 g/cm³
- Scale division: 0,001 g/cm³
- Standard: DIN 12791
- Type: designation: M50-075
- Length: 260 mm
Recently viewed
You may also like
Questions about Density areometer 0,750-0,800
What is this article?
Density areometer 0,750-0,800 is the article on this page. Luminix Health distributes Witeg for laboratory use. It sits in Hydrometers, inside Density & viscosity measurement, in Lab instruments.
A hydrometer floats in a liquid and the stem reading is the density or a related scale such as Brix. The liquid has to be at the temperature printed on the stem, or a correction is required. A chip on the stem changes the reading. One hydrometer does not cover every density.
Density is mass divided by volume. A hydrometer floats at a depth that depends on the density of the liquid. A pycnometer is a vessel of known volume that is weighed full. Viscosity is the resistance to flow. A capillary viscometer times how long a volume takes to fall through a tube. Both measurements need a stated temperature, because liquids change density and viscosity as they warm. The units trace to the BIPM and to NIST.
Which category should I open next?
The category is Density & viscosity measurement. The sub-category is Hydrometers. The catalogue is Lab instruments.
Shelves beside this one are Viscometers and Density meters & pycnometers.
What should I check before I order?
When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.
How does ordering and shipping work?
Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.
Which other categories should I open?
The seven catalogues are Labware, Lab chemicals, Lab instruments, Lab consumables, Chromatography equipment, Lab safety equipment and Life Science & Microbiology.