Description
Drying and heating oven M260-400V is engineered for material testing and ageing work across a temperature range from +14 °C above ambient up to +300 °C. High temperature accuracy is provided by APT.line™ technology with reinforced heating performance, complemented by a powerful adjustable-speed fan that generates high air throughput for rapid heating. The exhaust air flap is electromechanically controlled, and an intuitive touchscreen controller supports time-segment as well as real-time programming. Two chrome-plated shelves are supplied with the unit. Protective functions include a Class 2 temperature selector limiter (DIN 12880) and a Class 3.1 temperature selector monitor (DIN 12880) with optical/acoustic alarm selectable on the controller, together with a failsafe backup Pt 100 sensor. An Ethernet computer interface and an internal data logger with USB readout of measured values in open format facilitate documentation and process oversight. From manufacturer Binder, the M series combines a maximum temperature of +300 °C with versatile programming, making it suitable for demanding laboratory and industrial thermal testing under forced convection.
This article is part of Drying ovens & climate chambers, in Heating, drying & cooling.
Key features
- Pack size: 1 pc
- Temperature range: +14 °C above ambient to +300 °C
- Max. operating temperature: 300 °C
- Forced-air circulation: Yes
- Controller: Intuitive touchscreen with time-segment and real-time programming
- Safety: Class 2 limiter and Class 3.1 monitor (DIN 12880), failsafe Pt 100
- Manufacturer: Binder
- UNSPSC: 41104501
- Interior dimensions: 650 × 505 × 780 mm (W × D × H)
- Exterior dimensions: 810 × 786 × 962 mm (W × D × H)
- Weight, empty: 86 kg
- Voltage: 400 V, 50/60 Hz
- Nominal power: 3.1 kW
- Temperature uniformity at 150 °C: ±1.5 K
- Temperature fluctuation at 150 °C: ±0.4 K
- Heating-up time to 150 °C: 13 min
- Recovery time after a 30 s door opening at 150 °C: 6 min
- Air change rate at 100 °C: 65 x/h
- Shelves, standard / maximum: 2/8
- Load per rack: 40 kg
- Permitted load: 270 kg
- Energy consumption at 100 °C: 370 Wh/h
- Energy consumption at 150 °C: 560 Wh/h
- Wall clearance, side: 100 mm
- Wall clearance, back: 160 mm
- Sound pressure level: 46 dB(A)
- Data Sheet:
Recently viewed
You may also like
Questions about Drying and heating chambers M260-400V
What is this article?
Drying and heating chambers M260-400V is the article on this page. Luminix Health distributes Binder for laboratory use. It sits in Drying ovens & climate chambers, inside Heating, drying & cooling, in Lab instruments.
A drying oven holds a temperature above ambient to drive off water or to condition a sample. A climate chamber also holds humidity. Uniformity across the chamber, not only the set point, decides whether two samples on different shelves saw the same conditions.
Temperature equipment either holds a set point or drives a sample toward one. An oven dries. A furnace reaches the temperatures of ashing and melting. A bath surrounds a vessel with water or oil. A circulator moves that fluid. An incubator holds the mild warmth of a culture. An autoclave uses steam under pressure to sterilise. The number that matters is the temperature the article actually reaches, not the number painted on the dial. Temperature is part of the international system kept by the BIPM and compared by EURAMET.
Which category should I open next?
The category is Heating, drying & cooling. The sub-category is Drying ovens & climate chambers. The catalogue is Lab instruments.
Shelves beside this one are Muffle & tube furnaces, Heating mantles, Circulators, chillers & thermostats, Water & oil baths, Hot plates & heating blocks, Incubators, Heating & cooling (other), Temperature control accessories, Laboratory refrigerators & freezers, Autoclaves & sterilisers, Bunsen & gas burners and Heating tapes, cables & plates.
What should I check before I order?
When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.
How does ordering and shipping work?
Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.
Which other categories should I open?
The seven catalogues are Labware, Lab chemicals, Lab instruments, Lab consumables, Chromatography equipment, Lab safety equipment and Life Science & Microbiology.