Model 5430 benchtop centrifuge, Air-cooled or without cooling function,

Catalog nr. 1K2L.1
Eppendorf

Volume: 1 pc(s)
Value Packs: 1 piece
Price:
Sale price€4.583,80
Ask quote for bulk order

Description

Model 5430 benchtop centrifuge, Air-cooled or without cooling function,, Incl. FA-45-30-11 microlitre rotor for 30 reaction vials of 1.5/2.0 ml with aerosol-tight lid. Max. speed 14,000 rpm and 20,817 x g.

Features:
  • Menu-guided, multilingual operation and backlit LCD display
  • Five program keys for routine programs
  • Automatic rotor and load imbalance detection
  • Depending on the rotor, suitable for max. 6 x 50 ml Falcon® centrifuge tubes, or 2 MTPs or DWPs, or for 1.5 or 5 ml reaction vials
  • Automatic rotor detection
  • Membrane keyboard
  • Air-cooled or without cooling function
Not a medical device / Not an IVD product
Delivery incl. type FA-45-30-11 microlitre rotor for 30 reaction vials of 1.5/2.0 ml with aerosol-tight lid. Max. speed 14,000 rpm and 20,817 x g.
Technical Information
Type 5430 
Max. speed (in microlitre rotor) 14000 rpm
Additional data Speed can be adjusted in increments of 100 rpm 
Maximum RCF 20817 x g 
Minimum speed 100 rpm
Timer function 30 s to 99 min/continuous operation/short spin 
W x D x H 330 x 420 x 250 mm
Weight 29 kg
Mains connection 230 V, 50/60 Hz 

Recently viewed

You may also like

Questions about Model 5430 benchtop centrifuge, Air-cooled or without cooling function,

What is this article?

Model 5430 benchtop centrifuge, Air-cooled or without cooling function, is the article on this page. Luminix Health distributes Eppendorf for laboratory use. It sits in Benchtop & floor-standing centrifuges, inside Centrifuges, in Lab instruments.

A benchtop centrifuge sits on the bench and takes the ordinary tube rotors. A floor-standing model takes larger rotors and higher forces. Capacity, maximum force and which rotors are sold for it are the specification. Refrigeration is a separate choice, for samples that cannot warm.

A centrifuge separates by density. The rotor spins the sample and the force is reported as a multiple of gravity, not as a raw speed, because the same revolutions per minute are a different force at a different radius. A microcentrifuge takes small tubes. A benchtop or floor model takes larger rotors. The tube, the adapter and the rotor have to be the combination the manufacturer rated. An unbalanced load is how centrifuges fail. Measurement of the related quantities sits with the BIPM.

Which category should I open next?
What should I check before I order?

The technical information on this page is the manufacturer's sheet. Read that, not a rewritten specification.

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?