Description

NucleoSpin DNA Stool (250) is a complete spin-column kit for the isolation of DNA from stool samples, supplied as 250 preps. The package includes NucleoSpin DNA Stool Columns, NucleoSpin Bead Tubes Type A, NucleoSpin Inhibitor Removal Columns, collection tubes and the required buffers, enabling efficient sample disruption and inhibitor removal prior to nucleic acid purification. Designed for molecular biology workflows that process faecal material, the kit supports recovery of DNA suitable for downstream analytical methods. This configuration from manufacturer Macherey-Nagel is intended for laboratories handling higher sample throughput and provides all core plasticware and reagents needed for the stated prep number in one package. Bead tubes facilitate mechanical lysis of complex stool matrices, while dedicated inhibitor-removal columns help reduce co-purified substances that can interfere with subsequent enzymatic reactions. The kit is offered as a single package unit for straightforward stock management in research and diagnostic-support settings focused on stool-derived DNA isolation.

This article is part of DNA & RNA extraction kits, in Molecular biology.

Key features

  • Pack size: 250 preps
  • Storage temperature: 18–25 °C
  • Product type: DNA isolation kit for stool
  • Kit components: NucleoSpin DNA Stool Columns, Bead Tubes Type A, Inhibitor Removal Columns, collection tubes, buffers
  • EAN: 4046681160899
  • Technical Information Sheet: PDF
  • Safety Data Sheet: PDF

Compliance & Safety Information

GHS02 Danger

Hazard Statements (H-Phrases)

H226 Flammable liquid and vapour
H302 Harmful if swallowed
H314 Causes severe skin burns and eye damage
H315 Causes skin irritation
H319 Causes serious eye irritation
H336 May cause drowsiness or dizziness
H412 Harmful to aquatic life with long lasting effects

Precautionary Statements (P-Phrases)

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P233 P233 – No description available
P240 P240 – No description available
P241 P241 – No description available
P242 P242 – No description available
P243 P243 – No description available
P260sh P260sh – No description available
P261 P261 – No description available
P264 P264 – No description available
P264W P264W – No description available
P270 P270 – No description available
P271 P271 – No description available
P273 P273 – No description available
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P280sh P280sh – No description available
P301+P312 P301+P312 – No description available
P301+P330+P331 IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
P302+P352 IF ON SKIN: Wash with plenty of water.
P303+P361+P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P310 Immediately call a POISON CENTER/doctor.
P312 P312 – No description available
P330 P330 – No description available
P332+P313 P332+P313 – No description available
P337+P313 P337+P313 – No description available
P362+P364 P362+P364 – No description available
P363 P363 – No description available
P370+P378 P370+P378 – No description available
P403+P233 P403+P233 – No description available
P403+P235 P403+P235 – No description available
P405 P405 – No description available

Recently viewed

You may also like

Questions about NucleoSpin DNA Stool (250)

What is this article?

NucleoSpin DNA Stool (250) is the article on this page. Luminix Health distributes Macherey-Nagel for laboratory use. It sits in DNA & RNA extraction kits, inside Molecular biology, in Life Science & Microbiology.

An extraction kit lyses the sample and then binds the nucleic acid, usually on a column or on a bead, and washes the rest away. Kits for blood, tissue, soil or a PCR cleanup are different chemistries. Yield and the size of fragments they keep are in the protocol. An RNA kit has to protect against RNase.

Molecular biology here is the handling of DNA and RNA. Extraction kits break the cell and then separate the nucleic acid from protein and from the other nucleic acid. PCR and qPCR reagents copy a chosen sequence so it can be seen. The enzymes and the nucleotides are what the copy depends on. Nuclease contamination destroys the sample before the kit can save it. Sequences are on NCBI Nucleotide. Papers are on PubMed.

Which category should I open next?
What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?