NucleoSpin Virus (250)

Catalog nr. 740983250
Macherey-Nagel

Price:
Sale price€1.125,00
Ask quote for bulk order

Description

NucleoSpin Virus (250) is a complete spin-column kit for the isolation of viral RNA and DNA from serum and plasma. The package supports 250 preparations and is intended for molecular biology and diagnostic sample-preparation workflows that require reliable recovery of viral nucleic acids from liquid clinical matrices.

This article is part of DNA & RNA extraction kits, in Molecular biology.

Each kit supplies NucleoSpin Virus Columns, collection tubes, dedicated buffers, Liquid Proteinase K, and Carrier RNA, so laboratories can process samples with a matched set of consumables and reagents. The silica-membrane column format is suited to routine extraction of viral genomes prior to downstream amplification or detection methods. Packaged as one kit unit with a net weight of 2,92 kg, it fits high-throughput or multi-user laboratory settings where consistent prep capacity is needed.

This configuration comes from manufacturer Macherey-Nagel and is positioned for serum and plasma workflows rather than solid tissue. Components are provided ready for the stated prep count, helping standardize viral nucleic-acid isolation across batches. Use according to the kit protocol and applicable laboratory safety guidance for the included buffer system.

Key features

  • Pack size: 250 preps
  • Storage temperature: 18 - 25 °C
  • Kit contents: NucleoSpin Virus Columns, collection tubes, buffers, Liquid Proteinase K, Carrier RNA
  • EAN: 4046681155079
  • Technical Information Sheet: PDF
  • Safety Data Sheet: PDF

Compliance & Safety Information

GHS02, flammableGHS07, harmfulGHS08, health hazardDanger

Hazard Statements (H-Phrases)

H226Flammable liquid and vapour. H302Harmful if swallowed. H315Causes skin irritation. H319Causes serious eye irritation. H334May cause allergy or asthma symptoms or breathing difficulties if inhaled. H336May cause drowsiness or dizziness.

Precautionary Statements (P-Phrases)

P210Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P233Keep container tightly closed. P240Ground and bond container and receiving equipment. P241Use explosion-proof [electrical/ventilating/lighting] equipment. P242Use non-sparking tools. P243Take action to prevent static discharges. P261Avoid breathing dust/fume/gas/mist/vapours/spray. P261shAvoid breathing dust/fume/gas/mist/vapours/spray. P264Wash thoroughly after handling. P264WWash thoroughly after handling. P270Do not eat, drink or smoke when using this product. P271Use only outdoors or in a well-ventilated area. P280Wear protective gloves/protective clothing/eye protection/face protection. P280shWear protective gloves/protective clothing/eye protection/face protection. P284[In case of inadequate ventilation] wear respiratory protection. P301+P312IF SWALLOWED: Call a POISON CENTRE/doctor if you feel unwell. P302+P352IF ON SKIN: Wash with plenty of water. P303+P361+P353IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower]. P304+P340IF INHALED: Remove person to fresh air and keep comfortable for breathing. P305+P351+P338IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P312Call a POISON CENTRE/doctor if you feel unwell. P330Rinse mouth. P332+P313If skin irritation occurs: Get medical advice/attention. P337+P313If eye irritation persists: Get medical advice/attention. P342+P311If experiencing respiratory symptoms: Call a POISON CENTER/doctor. P362+P364Take off contaminated clothing and wash it before reuse. P370+P378In case of fire: Use to extinguish. P403+P233Store in a well-ventilated place. Keep container tightly closed. P403+P235Store in a well-ventilated place. Keep cool. P405Store locked up. P501Dispose of contents/container to.

Recently viewed

You may also like

Questions about NucleoSpin Virus (250)

What is this article?

NucleoSpin Virus (250) is the article on this page. Luminix Health distributes Macherey-Nagel for laboratory use. It sits in DNA & RNA extraction kits, inside Molecular biology, in Microbiology lab supplies.

An extraction kit lyses the sample and then binds the nucleic acid, usually on a column or on a bead, and washes the rest away. Kits for blood, tissue, soil or a PCR cleanup are different chemistries. Yield and the size of fragments they keep are in the protocol. An RNA kit has to protect against RNase.

Molecular biology here is the handling of DNA and RNA. Extraction kits break the cell and then separate the nucleic acid from protein and from the other nucleic acid. PCR and qPCR reagents copy a chosen sequence so it can be seen. The enzymes and the nucleotides are what the copy depends on. Nuclease contamination destroys the sample before the kit can save it. Sequences are on NCBI Nucleotide. Papers are on PubMed.

Which category should I open next?
What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?