ADAP BLOODTUBE SHORT F/LARGE BORE (5430)

Catalog nr. 5427742000
Eppendorf

Prix:
Prix réduit€106,81
Demander un devis pour commande en gros

Besoin d'une assistance technique ?

info@luminixhealth.com +32 13 30 43 61

Description

Adapter for blood collection tubes, short, large bore 5430 is a centrifuge accessory for one reaction vessel of 65 – 89 mm length. It is designed for rotor F-35-6-30 and fits the large rotor bore, providing a secure interface for shorter blood collection tubes in the corresponding rotor openings. Delivered as two pieces, the adapter supports laboratory centrifugation of blood collection tubes in clinical, diagnostic and research settings that use the large-bore configuration of this rotor. The short tube range of 65 – 89 mm aligns with common blood collection formats, while the large bore match ensures correct mechanical fit in the designated rotor positions. This accessory from Eppendorf is intended specifically for the F-35-6-30 rotor system and related blood collection tube handling. Net weight is 0,108 kg, gross weight 0,120 kg, and packaging volume 0,002 m³. As dedicated centrifuge accessory hardware for short tubes in the large bore of rotor F-35-6-30, it enables laboratories to equip the rotor for reproducible short-tube blood collection workflows.

This article is part of Rotor adapters & accessories, in Centrifuges.

Key features

  • Pack size: 2 pc(s)
  • Compatible rotor: F-35-6-30
  • Tube length range: 65 – 89 mm
  • Rotor bore: Large
  • Capacity: 1 reaction vessel per adapter

Besoin d'une assistance technique ?

info@luminixhealth.com +32 13 30 43 61

Récemment consulté

Vous aimerez peut-être aussi

Questions about ADAP BLOODTUBE SHORT F/LARGE BORE (5430)

What is this article?

ADAP BLOODTUBE SHORT F/LARGE BORE (5430) is the article on this page. Luminix Health distributes Eppendorf for laboratory use. It sits in Rotor adapters & accessories, inside Centrifuges, in Instruments de précision.

An adapter lets a rotor spun for large tubes accept smaller ones. The adapter has to be the one for that rotor, and the tubes have to be supported at the shoulder the adapter was designed for. A stack of the wrong inserts is an unbalanced load.

A centrifuge separates by density. The rotor spins the sample and the force is reported as a multiple of gravity, not as a raw speed, because the same revolutions per minute are a different force at a different radius. A microcentrifuge takes small tubes. A benchtop or floor model takes larger rotors. The tube, the adapter and the rotor have to be the combination the manufacturer rated. An unbalanced load is how centrifuges fail. Measurement of the related quantities sits with the BIPM.

Which category should I open next?
What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?