Analoges Leitfähigkeitsmessgerät LAT

Catalog nr. 102015920
LAT

Prix:
Prix réduit€415,67
Demander un devis pour commande en gros

Besoin d'une assistance technique ?

info@luminixhealth.com +32 13 30 43 61

Description

Analogue conductivity meter LAT is a compact laboratory instrument for continuous monitoring of water quality via electrical conductivity and temperature. The conductivity measuring range extends from 0,055 to 199,9 µS/cm, while temperature is covered from 0,1 to 99,9 °C, supporting both ultrapure and process-water applications. Limit values can be set steplessly between 0,055 and 30 µS/cm, enabling straightforward threshold control. The unit operates from a standard 230 V / 50–60 Hz supply and features an R3/4'' thread for direct inline installation. Two hoses—one for raw water and one for pure water—each 1,5 m long are included, allowing immediate connection to existing water lines. Manufactured by LAT and supplied as a complete single unit, the analogue meter provides reliable, easy-to-read conductivity surveillance for laboratory pure-water systems, rinse circuits and quality-control points where continuous analogue indication is preferred.

This article is part of Conductivity meters & cells, in pH & electrochemistry. See also pH meters.

Key features

  • Pack size: 1 pc
  • Conductivity range: 0,055 - 199,9 µS/cm
  • Temperature range: 0,1 - 99,9 °C
  • Limit setting: 0,055 - 30 µS/cm, stepless
  • Electrical connection: 230 V / 50 - 60 Hz
  • Thread: R3/4''
  • Technical Information Sheet: PDF

Besoin d'une assistance technique ?

info@luminixhealth.com +32 13 30 43 61

Récemment consulté

Vous aimerez peut-être aussi

Questions about Analoges Leitfähigkeitsmessgerät LAT

What is this article?

Analoges Leitfähigkeitsmessgerät LAT is the article on this page. Luminix Health distributes LAT for laboratory use. It sits in Conductivity meters & cells, inside pH & electrochemistry, in Instruments de précision.

A conductivity meter and its cell measure how well a solution carries current. The cell constant is the geometry that converts conductance to conductivity, and it is calibrated with a standard. Temperature compensation matters because conductivity rises with temperature.

A pH meter is a voltmeter on a glass electrode. The voltage tracks hydrogen-ion activity, and the electrode is converted to pH only after it is adjusted with buffers of known value. Conductivity measures how well a solution carries a current, which for dilute salts tracks concentration. Dissolved oxygen and titration are further electrodes on the same idea: a sensor, a standard, and a reading that is only as fresh as the calibration. Buffer values and chemical identity sit on PubChem. Accreditation of the calibration laboratory is the field of BELAC and EURAMET.

Which category should I open next?
What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.