Description
Analog Shore hardness tester SAUTER HBD, 100-0 is a handy Shore durometer with drag pointer designed for measuring indentation depth on the Shore D scale. It is recommended especially for internal comparative measurements; norm calibrations such as those to DIN 48-4 cannot be performed owing to the very narrow standard tolerances. Shore D hardness testing is typically applied to harder plastics and related materials where a portable analogue instrument is preferred. Max mode retains the peak value via the drag pointer so the reading can be noted after the test. The device can be mounted on the SAUTER TI-D test stand for more reproducible loading. Delivered from manufacturer Kern in a plastic box as one complete unit, this analogue Shore D tester supports routine hardness comparison and incoming-goods checks in laboratory and production settings that require a compact, stand-mountable durometer.
This article is part of pH meters, in pH & electrochemistry.
Key features
Récemment consulté
Vous aimerez peut-être aussi
Browse related categories
Category
Sub-category
Catalogue
Brand
Questions about Analogue Shore Hardness Tester SAUTER, HBD 100-0
What is this article?
Analogue Shore Hardness Tester SAUTER, HBD 100-0 is the article on this page. Luminix Health distributes KERN for laboratory use. It sits in pH meters, inside pH & electrochemistry, in Instruments de laboratoire.
A pH meter reads the electrode and displays pH, after calibration with at least two buffers. A meter that cannot be calibrated is a voltmeter. Resolution to 0.001 is not the same as accuracy. Portable and benchtop meters differ in the electrodes they accept and in the data they store.
A pH meter is a voltmeter on a glass electrode. The voltage tracks hydrogen-ion activity, and the electrode is converted to pH only after it is adjusted with buffers of known value. Conductivity measures how well a solution carries a current, which for dilute salts tracks concentration. Dissolved oxygen and titration are further electrodes on the same idea: a sensor, a standard, and a reading that is only as fresh as the calibration. Buffer values and chemical identity sit on PubChem. Accreditation of the calibration laboratory is the field of BELAC and EURAMET.
Which category should I open next?
The category is pH & electrochemistry. The sub-category is pH meters. The catalogue is Instruments de laboratoire.
Shelves beside this one are pH electrodes & sensors, Conductivity meters & cells, Dissolved oxygen & multiparameter meters, Titrators & electrochemistry systems and pH & electrochemistry accessories.
What should I check before I order?
When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.
How does ordering and shipping work?
Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.
Which other categories should I open?
The seven catalogues are Labware, Lab chemicals, Lab instruments, Lab consumables, Chromatography equipment, Lab safety equipment and Life Science & Microbiology.

