Description
Hydrometer ASTM 88H 0,950-1,000:0,005 is a laboratory hydrometer for liquid density work in the range 0,950 to 1,000 with a scale division of 0,005. The ASTM 88H designation identifies this instrument within the standardised hydrometer series used when readings are required in a narrow interval around and just below unity. Its 0,005 graduation supports clear scale interpretation during immersion measurements in routine analytical and quality-control workflows. Supplied as 1 pc, the unit has a net weight of 0,091 kg and a gross weight of 0,091 kg, making it a compact choice for bench-top density checks whenever sample values fall inside 0,950–1,000. Laboratories select the ASTM 88H type to match the working window of their liquids and to keep consecutive measurements comparable across the stated band. This hydrometer from manufacturer Witeg sits alongside related ASTM models that cover neighbouring ranges, so users can step through density intervals with consistent instrument geometry and scale logic. Origin data indicate manufacture in Germany. The device is intended for professional laboratory environments that rely on ASTM-type hydrometers for reproducible characterisation of liquids within the printed scale limits.
This article is part of Hydrometers, in Density & viscosity measurement.
Key features
- Pack size: 1 pc
- Type: ASTM hydrometer 88H
- Scale range: 0,950–1,000
- Scale division: 0,005
Récemment consulté
Vous aimerez peut-être aussi
Questions about Areometer ASTM 88H 0,950-1,000:0,005
What is this article?
Areometer ASTM 88H 0,950-1,000:0,005 is the article on this page. Luminix Health distributes Witeg for laboratory use. It sits in Hydrometers, inside Density & viscosity measurement, in Instruments de laboratoire.
A hydrometer floats in a liquid and the stem reading is the density or a related scale such as Brix. The liquid has to be at the temperature printed on the stem, or a correction is required. A chip on the stem changes the reading. One hydrometer does not cover every density.
Density is mass divided by volume. A hydrometer floats at a depth that depends on the density of the liquid. A pycnometer is a vessel of known volume that is weighed full. Viscosity is the resistance to flow. A capillary viscometer times how long a volume takes to fall through a tube. Both measurements need a stated temperature, because liquids change density and viscosity as they warm. The units trace to the BIPM and to NIST.
Which category should I open next?
The category is Density & viscosity measurement. The sub-category is Hydrometers. The catalogue is Instruments de laboratoire.
Shelves beside this one are Viscometers and Density meters & pycnometers.
What should I check before I order?
When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.
How does ordering and shipping work?
Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.
Which other categories should I open?
The seven catalogues are Labware, Lab chemicals, Lab instruments, Lab consumables, Chromatography equipment, Lab safety equipment and Life Science & Microbiology.





