Mercury(II) sulphate solution 80 g/l in, potassium dichromate 0,02 mol/l , 1 l

Catalog nr. X871.1
Carl Roth

Volume: 1 liter
Value Packs: 1 piece
Prix:
Prix réduit€147,85
Demander un devis pour commande en gros

Besoin d'une assistance technique ?

info@luminixhealth.com +32 13 30 43 61

Description

Mercury(II) sulphate solution 80 g/l is a ready-to-use volumetric reagent formulated in potassium dichromate 0,02 mol/l and sulphuric acid for laboratory titration applications. The defined 80 g/l mercury(II) sulphate content supports analytical workflows that require this matrix, including methods linked to chemical oxygen demand and related volumetric procedures. With a density of 1,19 g/cm³, the solution is It forms part of the ready-to-use volumetric standard solutions range for titration. Offered by manufacturer Carl ROTH, the product helps laboratories avoid separate preparation of the mercury(II) sulphate component in a dichromate–sulphuric acid system. Classification under UN number 3289 indicates the need for controlled handling in professional settings. This reagent is intended for trained laboratory personnel performing standardised volumetric analyses where consistent concentration and a practical pack size are essential.

This article belongs on Volumetric standard solutions (titration), in Analytical standards & reference materials.

Key features

  • Titer: 0,998-1,002
  • Amount-of-substance conc. (20 °C): 0.01996-0.02004 mol/l
  • Pack sizes: 1 l, 2.5 l
  • Density: 1,19 g/cm³
  • Concentration: 80 g/l mercury(II) sulphate
  • Matrix: potassium dichromate 0,02 mol/l in sulphuric acid
  • UN nr.: 3289
  • CAS number: 7783-35-9
  • Technical Information Sheet: PDF
  • Safety Data Sheet: PDF

Besoin d'une assistance technique ?

info@luminixhealth.com +32 13 30 43 61

Compliance & Safety Information

GHS05GHS06GHS08GHS09 Danger

Hazard Statements (H-Phrases)

H290 May be corrosive to metals
H300+ H300+ – No description available
H310+ H310+ – No description available
H330 Fatal if inhaled
H314 Causes severe skin burns and eye damage
H340 May cause genetic defects
H350 May cause cancer
H360FD H360FD – No description available
H373 May cause damage to organs through prolonged or repeated exposure
H411EU H411EU – No description available
H208 H208 – No description available

Precautionary Statements (P-Phrases)

P273 P273 – No description available
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P303+P361+P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P308+P313 IF exposed or concerned: Get medical advice/attention.

Récemment consulté

Vous aimerez peut-être aussi

Questions about Mercury(II) sulphate solution 80 g/l in, potassium dichromate 0,02 mol/l , 1 l

What is this article?

Mercury(II) sulphate solution 80 g/l in, potassium dichromate 0,02 mol/l , 1 l is the article on this page. Luminix Health distributes Carl Roth for laboratory use. It sits in Volumetric standard solutions (titration), inside Analytical standards & reference materials, in Produits chimiques de laboratoire et industriels.

A volumetric standard solution is a reagent of stated concentration for titration, such as a stated molarity of acid, base or silver nitrate. The factor or the exact titre is on the certificate. Using the nominal molarity when a factor is printed is a systematic error.

A reference material is the article against which another result is compared. Its value is stated, and the uncertainty of that value is part of the product. An ICP or ion standard is a solution of known concentration. A volumetric standard is for titration. A chromatography standard is the peak you match. The grade names, including pharmacopoeia and ASTM, say which impurities were limited. Identity is checked on PubChem. Names follow IUPAC. Medicinal grades follow the European Pharmacopoeia and USP.

Which category should I open next?
What should I check before I order?

The technical information on this page is the manufacturer's sheet. Read that, not a rewritten specification.

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?