Beschrijving
ROTI®Pol ProofRead (1 x 40 µl), 5 U/µl, Storage temp. -20 °C
For PCR. Recombinant, heat stable DNA polymerase from the thermophilic bacterium Thermus aquaticus or Pyrococcus furiosus.
ROTI®Pol, the series of DNA polymerases is the optimal choice for all PCR cycling protocols, as being performed in, for instance, analysis of cloning efficiency, for gene fishing, in routine screening processes, educational assays and much more. In combination with our specially designed buffers, the ROTI®Pol DNA polymerases deliver specific and reproducible PCR amplification with a wide range of PCR templates.
Recombinant version of the heat stable Pfu DNA polymerase from the extreme thermophilic archae bacterium Pyrococcus furiosus in storage buffer, plus additional 10x concentrated PCR-ProofRead reaction buffer. ROTI®Pol ProofRead is recommended for use in all PCR applications in which exact sequence fidelity is required.This polymerase set ROTI®Pol ProofRead is the optimal choice for all high fidelity PCR assays, as being performed, for instance, prior to cloning or sequencing, in cycle sequencing or in site-directed mutagenesis reactions. In combination with the attached specially adjusted buffer, the ProofRead polymerase delivers sequence identical PCR amplificates of good yield with a wide range of PCR templates. Additionally, ROTI®Pol ProofRead is well suited for amplification of target sequences of high GC content, or with complex secondary structures.ROTI®Pol ProofRead is able to amplify PCR products up to 3 kb with genomic DNA and is appropriate for use in the amplification of a broad variety of template DNAs. The ProofRead DNA polymerase included in the set replicates DNA 5’ → 3’ at 72 °C to 75 °C under presence of magnesium ions. Furthermore, the ProofRead-DNA polymerase possesses a 3’ → 5’ (proof reading) exonuclease activity, rapidly substituting misincorporated bases during polymerization, and thus being responsible for the high sequence fidelity. ROTI®Pol ProofRead generated DNA fragments are blunt-ended.
Filled in colour coded tubes, the set contains the DNA polymerase and a 10x concentrated proof-reading reaction buffer with 20 mM MgSO4.
ProofRead polymerase in storage buffer containing 50 % glycerol, PCR ProofRead buffer (10x) with 20 mM MgSO4. Colour coded tubes.Contents of this set may not be bought separately.
| Application | High fidelity PCR with exact sequence replication |
| Amplicon ends | blunt |
| Polymerase | Proof reading / high fidelity Pfu polymerase |
| Reaction buffer | ProofRead |
| Use | High fidelity PCR with exact sequence replication |
Recently viewed
You may also like
Browse related categories
Category
Sub-category
PCR, qPCR & nucleic acid analysis reagents
Catalogue
Brand
Questions about ROTI®Pol ProofRead (1 x 40 µl), 5 U/µl, 40 µl, plastic
What is this article?
ROTI®Pol ProofRead (1 x 40 µl), 5 U/µl, 40 µl, plastic is the article on this page. Luminix Health distributes Carl Roth for laboratory use. It sits in PCR, qPCR & nucleic acid analysis reagents, inside Molecular biology, in Media.
PCR and qPCR reagents are the polymerase, the nucleotides, the buffer and often a ready master mix, plus the dyes a real-time instrument reads. Hot-start enzymes and proofreading enzymes are different tools. A master mix already contains nucleotides. Adding them again is a failed reaction.
Molecular biology here is the handling of DNA and RNA. Extraction kits break the cell and then separate the nucleic acid from protein and from the other nucleic acid. PCR and qPCR reagents copy a chosen sequence so it can be seen. The enzymes and the nucleotides are what the copy depends on. Nuclease contamination destroys the sample before the kit can save it. Sequences are on NCBI Nucleotide. Papers are on PubMed.
Which category should I open next?
The category is Molecular biology. The sub-category is PCR, qPCR & nucleic acid analysis reagents. The catalogue is Media.
Shelves beside this one are DNA & RNA extraction kits and Molecular biology reagents (other).
What should I check before I order?
The technical information on this page is the manufacturer's sheet. Read that, not a rewritten specification.
When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.
How does ordering and shipping work?
Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.
Which other categories should I open?
The seven catalogues are Labware, Lab chemicals, Lab instruments, Lab consumables, Chromatography equipment, Lab safety equipment and Life Science & Microbiology.