GC capillary columns

889 products

Weergeven 73 - 96 van 889 producten

Weergeven 73 - 96 van 889 producten
Bekijken
GC-Capillary column ROTI®Cap-5, L 60 m, inner Ø 0.25 mm, thick 0.10 µm - Luminix HealthCarl Roth
Kies opties
GC-Capillary column ROTI®Cap-5, L 50 m, inner Ø 0.32 mm, thick 5.00 µm - Luminix HealthCarl Roth
Kies opties
GC-Capillary column ROTI®Cap-5, L 50 m, inner Ø 0.32 mm, thick 0.50 µm - Luminix HealthCarl Roth
Kies opties
GC-Capillary column ROTI®Cap-5, L 50 m, inner Ø 0.32 mm, thick 0.25 µm - Luminix HealthCarl Roth
Kies opties
GC-Capillary column ROTI®Cap-5, L 60 m, inner Ø 0.25 mm, thick 1.00 µm - Luminix HealthCarl Roth
Kies opties
GC-Capillary column ROTI®Cap-5, L 50 m, inner Ø 0.25 mm, thick 1.00 µm - Luminix HealthCarl Roth
Kies opties
GC-Capillary column ROTI®Cap-5, L 25 m, inner Ø 0.53 mm, thick 2.00 µm - Luminix HealthCarl Roth
Kies opties
GC-Capillary column ROTI®Cap-5, L 25 m, inner Ø 0.32 mm, thick 1.00 µm - Luminix HealthCarl Roth
Kies opties
GC-Capillary column ROTI®Cap-5, L 25 m, inner Ø 0.32 mm, thick 0.10 µm - Luminix HealthCarl Roth
Kies opties
GC capillary column ROTI®Cap-5 HT, L 30m,Ø inner 0.32mm, film thick. 0,1µm - Luminix HealthCarl Roth
Kies opties
GC-Capillary column ROTI®Cap-5, L 30 m, inner Ø 0.53 mm, thick 0.50 µm - Luminix HealthCarl Roth
Kies opties
GC-Capillary column ROTI®Cap-5, L 50 m, inner Ø 0.20 mm, thick 0.35 µm - Luminix HealthCarl Roth
Kies opties
GC capillary column ROTI®Cap-5 HT, 15 m, 0.32 mm, 0.25 µm, non-polar - Luminix HealthCarl Roth
Kies opties
GC-Capillary column ROTI®Cap-5, L 50 m, inner Ø 0.25 mm, thick 0.25 µm - Luminix HealthCarl Roth
Kies opties
GC capillary column ROTI®Cap-5 HT, L 30m,Ø inner 0.25mm, film thick. 0,1µm - Luminix HealthCarl Roth
Kies opties
GC-Capillary column ROTI®Cap-5, L 25 m, inner Ø 0.25 mm, thick 1.00 µm - Luminix HealthCarl Roth
Kies opties
GC-Capillary column ROTI®Cap-5, L 25 m, inner Ø 0.25 mm, thick 0.50 µm - Luminix HealthCarl Roth
Kies opties
GC-Capillary column ROTI®Cap-5, L 25 m, inner Ø 0.32 mm, thick 3.00 µm - Luminix HealthCarl Roth
Kies opties
GC-Capillary column ROTI®Cap-5, L 25 m, inner Ø 0.32 mm, thick 0.25 µm - Luminix HealthCarl Roth
Kies opties
GC-Capillary column ROTI®Cap-5, L 60 m, inner Ø 0.32 mm, thick 0.35 µm - Luminix HealthCarl Roth
Kies opties
GC-Capillary column ROTI®Cap-5, L 50 m, inner Ø 0.32 mm, thick 3.00 µm - Luminix HealthCarl Roth
Kies opties
GC-Capillary column ROTI®Cap-5, L 50 m, inner Ø 0.32 mm, thick 1.00 µm - Luminix HealthCarl Roth
Kies opties

Recently viewed

Questions about GC capillary columns

Why GC capillary columns?

A GC capillary column is specified by the phase, the length, the internal diameter and the film thickness. A thicker film retains longer and takes a higher load. A narrow bore gives sharper peaks and needs a cleaner sample. The maximum temperature of the phase is a hard limit.

A GC capillary column is a long open tube with a stationary phase coated on the wall. The sample is a vapour, carried by gas. The phase, the film thickness, the length and the internal diameter decide which compounds separate and how long it takes. A liner is the glass sleeve in the injector. It is a consumable: it collects the non-volatile dirt. The septum and the syringe are the other parts that leak or shed. Compound identity sits on PubChem under IUPAC names.

This shelf belongs to GC columns & accessories, inside Chromatografie. Luminix Health distributes this range for laboratory use.

Which shelves sit beside this one?

The neighbouring shelves are GC liners, septa, syringes & accessories. The category above this shelf is GC columns & accessories.

How does ordering and shipping work?

Luminix Health distributes this range from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. Send a quote request, contact the team, or read who we are. The full brand index is on shop by brand.

Which other categories should I open?