ADAP BLOODTUBE LONG F/LARGE BORE (5430)

Catalog nr. 5427743006
Eppendorf

Preis:
Sonderpreis€106,81

Technische Unterstützung benötigt?

info@luminixhealth.com +32 13 30 43 61

Beschreibung

Blood collection tube adapter, long design with large bore (5430), is a centrifuge accessory for one reaction vessel measuring 90 – 110 mm in length. It is intended for the F-35-6-30 rotor and matches the large rotor bore, so longer blood-collection or reaction tubes sit securely during centrifugation. The set comprises two adapters and supports routine loading of elongated vessels in laboratory workflows that use this rotor geometry. Net weight is 0,105 kg and gross weight 0,116 kg, with a packaging volume of 0,002 m³. Originating from Germany (Saxony) and offered by manufacturer Eppendorf, the adapter provides a dedicated interface between the stated vessel length range and the large-bore positions of the F-35-6-30 rotor. Laboratories running this rotor can use the pair to hold a single 90 – 110 mm vessel per adapter position without additional conversion hardware. The long, large-bore configuration is specified expressly for that rotor opening size, enabling straightforward insertion and removal of tubes after the run. As centrifuge accessory hardware, it belongs to the standard adapter range for consistent vessel handling on the F-35-6-30 platform in everyday sample-processing applications.

This article is part of Rotor adapters & accessories, in Centrifuges.

Key features

  • Pack size: 2 pc(s)
  • Compatible rotor: F-35-6-30
  • Vessel capacity: 1 reaction vessel 90 – 110 mm
  • Rotor bore: large

Technische Unterstützung benötigt?

info@luminixhealth.com +32 13 30 43 61

Recent bekeken

Misschien vind je dit ook leuk

Questions about ADAP BLOODTUBE LONG F/LARGE BORE (5430)

What is this article?

ADAP BLOODTUBE LONG F/LARGE BORE (5430) is the article on this page. Luminix Health distributes Eppendorf for laboratory use. It sits in Rotor adapters & accessories, inside Centrifuges, in Präzisionsinstrumente.

An adapter lets a rotor spun for large tubes accept smaller ones. The adapter has to be the one for that rotor, and the tubes have to be supported at the shoulder the adapter was designed for. A stack of the wrong inserts is an unbalanced load.

A centrifuge separates by density. The rotor spins the sample and the force is reported as a multiple of gravity, not as a raw speed, because the same revolutions per minute are a different force at a different radius. A microcentrifuge takes small tubes. A benchtop or floor model takes larger rotors. The tube, the adapter and the rotor have to be the combination the manufacturer rated. An unbalanced load is how centrifuges fail. Measurement of the related quantities sits with the BIPM.

Which category should I open next?
What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.