ROTISZINT®Routine, NPE free LSC cocktail, ready-to-use, 500 ml, plastic

SKU: 1P1A.1

Volume: 500 ml
Value Packs: 1 piece
Preis:
Sonderpreis€61,20

Beschreibung

ROTISZINT®Routine, NPE free LSC cocktail, ready-to-use, for scintillation, Density (D) ~1 g/cm³, Flash point (flp) 149 °C, Boiling point (bp) >290 °C, Storage temp. +15 to +25 °C, UN-Nr. 3082

Multi-purpose, ready-to-use scintillation cocktails for Liquid Scintillation Counting (LSC) of β radiators (e.g. 3H, 14C, 32P, 35S) in aqueous samples. NPE-free

  • High counting efficiency
  • Very good quench resistance
  • High flash point
  • NPE free
  • Non-carcinogenic
  • According to 2003/53/ECC

The next generation ROTISZINT® Cocktails have been developed to replace nonylphenylethoxylates (NPE) with more user-friendly, sustainable reagents. In addition, these modern cocktails show even higher scintillation efficiency and higher sample holding capacity. ROTISZINT® cocktails are also pleasant to use due to their high flash point.ROTISZINT® scintillation cocktails may be used in all biological, biochemical and chemical areas. Typical applications are, for instance, the measurement of cell culture supernatants, routine analysis, enzymatic or flow-count assays in the field of research, development or analytics.The cocktails are according to Directive 2003/53/ECC of the European Parliament and Council

Directions for use

Wide excitation range between 190 and 370 nmEmission maximum: 420-430 nmOur modern ROTISZINT® cocktails contain the same reagents as primary and secondary scintillators that were used in ROTISZINT®Eco plus. Thus, neither the excitation nor the detection wavelength change for the application. We also recommend to use the same scintillation protocol in the first approaches with one of the new ROTISZINT® cocktails as was previously used with the ROTISZINT®Eco plus (0016) cocktail. In many cases, the parameters are directly transferable. If the scintillation results are not satisfactory at first, the sample quantity (the ratio sample/cocktail) can be readjusted.

Safe and easy-to-use scintillation cocktail for a wide range of applications. ROTISZINT®Routine has a good sample uptake capacity for all aqueous samples and is suitable for solutions with high ionic strength.

  • NPE free, non-carcinogenic
  • High counting efficiency
  • Low photo- and chemoluminescence
  • Very good colour- and chemical quench resistance
  • Virtually odor- and colourless
  • High flash point
  • No permeation through plastic vials

For some solvents, such as 0.3 M HNO3, the sample uptake capacity is up to 5 ml / 10 ml cocktail. For most common as well as for higher concentrated solutions (for example 0.1 M ammonium citrate, 0.1 M EDTA or 2 M HNO3) the maximum sample volume is 2 to 3.5 ml / 10 ml cocktail.

Application

Excellent for measuring solutions. For the measurement of filter samples we recommend the use of ROTISZINT®Filter.We recommend the use of ROTILABO®Dispensers.

Technical Information
Emissions maximum 420 nm 

Compliance & Safety Information

GHS05GHS08GHS09 Danger

Hazard Statements (H-Phrases)

H304 May be fatal if swallowed and enters airways
H315 Causes skin irritation
H318 Causes serious eye damage
H410 Very toxic to aquatic life with long lasting effects

Precautionary Statements (P-Phrases)

P280 Wear protective gloves/protective clothing/eye protection/face protection.
P301+P310 P301+P310 – No description available
P302+P352 IF ON SKIN: Wash with plenty of water.
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

You may also like

Recently viewed