Description
Dry Block Heater 3 is a digital block thermostat configured for three aluminium block inserts, delivering precise temperature control in small vessels. The supplied PT-1000 temperature sensor allows temperature regulation directly within the sample vessels. Compatible formats include PCR tubes, PCR strips, Greiner tubes, standard tubes, microtiter plates and cuvettes. This model from manufacturer IKA is ideal for melting and boiling point determinations, enzyme reactions, incubation and activation of cultures, immunoassays, DNA denaturation, culture media processing, coagulation studies, blood urea nitrogen determinations and in-situ hybridisations. Temperature is continuously adjustable up to 120 °C. A countdown timer can be set from 1 min to 99 h 59 min, and a counter shows the heating duration. Practical extras comprise an error code display, a fixed safety circuit and an acoustic signal when the run ends. Numerous available blocks make the instrument highly versatile for daily laboratory workflows. Pack size is 1 pc.
This article is part of Hot plates & heating blocks, in Heating, drying & cooling.
Key features
- Pack size: 1 pc
- Storage temperature: 5 °C – 40 °C
- Block capacity: 3 aluminium block inserts
- Temperature setting: continuous up to 120 °C
- Sensor: PT-1000 temperature probe included
- EAN: 4053411007430
Recently viewed
You may also like
Browse related categories
Category
Sub-category
Catalogue
Brand
Questions about Dry Block Heater 3, Dry block heater, 3 blocks
What is this article?
Dry Block Heater 3, Dry block heater, 3 blocks is the article on this page. Luminix Health distributes IKA for laboratory use. It sits in Hot plates & heating blocks, inside Heating, drying & cooling, in Lab instruments.
A hot plate heats a flat-bottom vessel from below, often with stirring. A heating block holds tubes in machined holes so each tube sees the same temperature. The block's hole diameter has to match the tube, or the heat never arrives.
Temperature equipment either holds a set point or drives a sample toward one. An oven dries. A furnace reaches the temperatures of ashing and melting. A bath surrounds a vessel with water or oil. A circulator moves that fluid. An incubator holds the mild warmth of a culture. An autoclave uses steam under pressure to sterilise. The number that matters is the temperature the article actually reaches, not the number painted on the dial. Temperature is part of the international system kept by the BIPM and compared by EURAMET.
Which category should I open next?
The category is Heating, drying & cooling. The sub-category is Hot plates & heating blocks. The catalogue is Lab instruments.
Shelves beside this one are Muffle & tube furnaces, Heating mantles, Circulators, chillers & thermostats, Drying ovens & climate chambers, Water & oil baths, Incubators, Heating & cooling (other), Temperature control accessories, Laboratory refrigerators & freezers, Autoclaves & sterilisers, Bunsen & gas burners and Heating tapes, cables & plates.
What should I check before I order?
When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.
How does ordering and shipping work?
Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.
Which other categories should I open?
The seven catalogues are Labware, Lab chemicals, Lab instruments, Lab consumables, Chromatography equipment, Lab safety equipment and Life Science & Microbiology.