LID FOR 18x2ML A-T QUICK ROTOR (5418/R)

Catalog nr. 5418708001
Eppendorf

Price:
Sale price€226,00
Ask quote for bulk order

Description

Lid for AT-QL rotor 18x2 ml (5418/R) is an aerosol-tight rotor lid designed for the FA-45-18-11 rotor used with Centrifuge 5418 and 5418R systems. Manufactured from aluminium, this cover supports secure closure of the fixed-angle rotor during high-speed microcentrifugation of 2 ml tubes, helping maintain containment when aerosol-tight operation is required in molecular biology, clinical, and routine laboratory workflows.

This article is part of Rotors, in Centrifuges.

Supplied as a single piece with a net weight of 0,270 kg (gross weight 0,300 kg), the lid is a dedicated spare or replacement component for the AT-QL rotor configuration. It belongs to the centrifuge accessories range from manufacturer Eppendorf and is intended for laboratories that need to restore or maintain aerosol-tight rotor performance on 5418/5418R instruments. The compact packaging volume of 0,003 m³ suits stock holding for service and routine maintenance. Use only with the matching FA-45-18-11 rotor and centrifuge models specified by the manufacturer to ensure correct fit and function in daily sample preparation.

Key features

  • Pack size: 1 pc
  • Product type: Aerosol-tight rotor lid
  • Compatibility: FA-45-18-11 rotor, Centrifuge 5418/5418R
  • Material: Aluminium
  • Technical Information Sheet: PDF

Recently viewed

You may also like

Questions about LID FOR 18x2ML A-T QUICK ROTOR (5418/R)

What is this article?

LID FOR 18x2ML A-T QUICK ROTOR (5418/R) is the article on this page. Luminix Health distributes Eppendorf for laboratory use. It sits in Rotors, inside Centrifuges, in Lab instruments.

A centrifuge rotor is the rotating part that holds the tubes, and it is rated for a maximum speed and a maximum load. A swing-out rotor and a fixed-angle rotor pellet differently. A rotor from another centrifuge does not belong on this drive, even when it seems to fit.

A centrifuge separates by density. The rotor spins the sample and the force is reported as a multiple of gravity, not as a raw speed, because the same revolutions per minute are a different force at a different radius. A microcentrifuge takes small tubes. A benchtop or floor model takes larger rotors. The tube, the adapter and the rotor have to be the combination the manufacturer rated. An unbalanced load is how centrifuges fail. Measurement of the related quantities sits with the BIPM.

Which category should I open next?
What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?