Description
A 11.2 cutting blade is a stainless-steel laboratory accessory designed for cutting soft, fibrous grinding materials during sample preparation. Made from AISI 440B stainless steel, the blade combines hardness with corrosion resistance so that moist or organic matrices can be processed cleanly and repeatedly. It is intended for fibrous feedstocks that benefit from a defined shearing action rather than pure impact milling. The A 11.2 is not included in the standard delivery of the A 11 basic mill and is therefore ordered as a dedicated accessory from manufacturer IKA. Supplied as a single piece with a net weight of only 0,003 kg, the compact blade fits readily into compatible grinding setups. Analytical, quality-control and research laboratories use it when preparing plant fibres, soft tissues and similar materials that require controlled particle reduction. Robust stainless-steel construction supports hygienic cleaning between batches and maintains cutting performance under typical laboratory milling conditions, making the blade a practical spare or upgrade for routine workflows.
This article is part of Mills, grinders & homogenisers, in Test sieves & mills.
Key features
Récemment consulté
Vous aimerez peut-être aussi
Questions about A 11.2, Cutting blade, stainless steel
What is this article?
A 11.2, Cutting blade, stainless steel is the article on this page. Luminix Health distributes IKA for laboratory use. It sits in Mills, grinders & homogenisers, inside Test sieves & mills, in Instruments de laboratoire.
A mill, grinder or homogeniser reduces particle size or breaks a tissue before an extraction. The rotor and the sieve insert decide the result. A knife mill and a bead mill are different machines. The sample has to tolerate the heat the motor puts into it.
A test sieve sorts particles by whether they pass an opening. Wire mesh and perforated plate are two ways of making that opening, and the nominal size is not a suggestion. A sieve shaker repeats the motion so the result does not depend on how hard someone shook by hand. A mill or grinder makes the particles smaller before they are sieved. The certificate of the sieve, and the opening size, are what an audit asks for. Measurement practice around mass and dimension sits with the BIPM, EURAMET and BELAC.
Which category should I open next?
The category is Test sieves & mills. The sub-category is Mills, grinders & homogenisers. The catalogue is Instruments de laboratoire.
Shelves beside this one are Test sieves (wire mesh), Test sieves (perforated plate), Sieve shakers and Sieve accessories (lids, pans, rings).
What should I check before I order?
When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.
How does ordering and shipping work?
Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.
Which other categories should I open?
The seven catalogues are Labware, Lab chemicals, Lab instruments, Lab consumables, Chromatography equipment, Lab safety equipment and Life Science & Microbiology.