Rack 14x15ml D17mm FA 2/pk

Catalog nr. 30553133
Ohaus

Prix:
Prix réduit€300,00
Demander un devis pour commande en gros

Besoin d'une assistance technique ?

info@luminixhealth.com +32 13 30 43 61

Description

Rack 14 × 15 ml D17 mm FA is a centrifuge accessory configured for fourteen 15 ml tubes with a 17 mm diameter in an FA layout. The product is offered as a two-piece pack for laboratory centrifugation and sample organisation tasks. Net weight is 0,99 kg and gross weight is 1,1 kg. Packaging dimensions are 0,28 m depth, 0,18 m width and 0,11 m height, with a packaging volume of 0,006 m³. This rack from manufacturer Ohaus is classified as a centrifuge accessory and is intended for secure holding of 15 ml tubes at the stated diameter during preparation and processing. Display devices are not included. The accessory originates from Germany and suits research and routine laboratory settings that require a higher tube count in a compact rack footprint. The defined 14-place geometry and 17 mm diameter support consistent loading of 15 ml vessels, while the two-piece pack facilitates stocking for multi-instrument or multi-user centrifuge environments without expanding bench storage demands.

This article is part of Rotor adapters & accessories, in Centrifuges.

Key features

  • Pack size: 2 pc(s)
  • Product type: Centrifuge Accessories
  • Configuration: 14 × 15 ml tubes
  • Tube diameter: 17 mm
  • Format: FA

Besoin d'une assistance technique ?

info@luminixhealth.com +32 13 30 43 61

Récemment consulté

Vous aimerez peut-être aussi

Questions about Rack 14x15ml D17mm FA 2/pk

What is this article?

Rack 14x15ml D17mm FA 2/pk is the article on this page. Luminix Health distributes Ohaus for laboratory use. It sits in Rotor adapters & accessories, inside Centrifuges, in Instruments de laboratoire.

An adapter lets a rotor spun for large tubes accept smaller ones. The adapter has to be the one for that rotor, and the tubes have to be supported at the shoulder the adapter was designed for. A stack of the wrong inserts is an unbalanced load.

A centrifuge separates by density. The rotor spins the sample and the force is reported as a multiple of gravity, not as a raw speed, because the same revolutions per minute are a different force at a different radius. A microcentrifuge takes small tubes. A benchtop or floor model takes larger rotors. The tube, the adapter and the rotor have to be the combination the manufacturer rated. An unbalanced load is how centrifuges fail. Measurement of the related quantities sits with the BIPM.

Which category should I open next?
What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?