Description
Hot air steriliser SF110 is a medical-device hot-air unit with a nominal volume of 108 l for controlled dry-heat sterilisation. The set temperature range is +20 °C to +250 °C, with a working range from at least 10 °C above ambient up to +250 °C. Forced air circulation supports uniform temperature distribution in the stainless-steel interior (560 × 480 × 400 mm). The appliance is delivered with two grid shelves and a stainless-steel door. Exhaust flap and fan speed are electronically adjustable from 0 % to 100 % in 10 % steps. An Ethernet interface allows readout of protocol data, and an integrated data logger provides storage capacity for at least 10 years. Double overtemperature protection and setting of three calibration values on the ControlCOCKPIT support safe routine use; a factory calibration certificate for +160 °C is included. The structured stainless-steel housing measures 745 × 864 × 584 mm and runs on 230 V, 50/60 Hz with a maximum power consumption of approximately 2800 W. This SingleDISPLAY model from manufacturer Memmert is intended for laboratory and clinical sterilisation workflows requiring documented hot-air processing.
This article is part of Autoclaves & sterilisers, in Heating, drying & cooling.
Key features
Récemment consulté
Vous aimerez peut-être aussi
Browse related categories
Category
Sub-category
Catalogue
Brand
Questions about Hot air steriliser SF110, 108l, 20-250°C
What is this article?
Hot air steriliser SF110, 108l, 20-250°C is the article on this page. Luminix Health distributes Memmert for laboratory use. It sits in Autoclaves & sterilisers, inside Heating, drying & cooling, in Instruments de laboratoire.
An autoclave sterilises with steam under pressure, typically 121 °C. A load that is wrapped wrong, or a liquid in a sealed full bottle, does not see that temperature, or it bursts. Chamber volume and the cycles it can run are the specification.
Temperature equipment either holds a set point or drives a sample toward one. An oven dries. A furnace reaches the temperatures of ashing and melting. A bath surrounds a vessel with water or oil. A circulator moves that fluid. An incubator holds the mild warmth of a culture. An autoclave uses steam under pressure to sterilise. The number that matters is the temperature the article actually reaches, not the number painted on the dial. Temperature is part of the international system kept by the BIPM and compared by EURAMET.
Which category should I open next?
The category is Heating, drying & cooling. The sub-category is Autoclaves & sterilisers. The catalogue is Instruments de laboratoire.
Shelves beside this one are Muffle & tube furnaces, Heating mantles, Circulators, chillers & thermostats, Drying ovens & climate chambers, Water & oil baths, Hot plates & heating blocks, Incubators, Heating & cooling (other), Temperature control accessories, Laboratory refrigerators & freezers, Bunsen & gas burners and Heating tapes, cables & plates.
What should I check before I order?
When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.
How does ordering and shipping work?
Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.
Which other categories should I open?
The seven catalogues are Labware, Lab chemicals, Lab instruments, Lab consumables, Chromatography equipment, Lab safety equipment and Life Science & Microbiology.

