Description
Hydrometer covering the density range 0,850–0,900 g/cm³ is a precision glass instrument built to DIN 12791 Serie M50 for laboratory density determination of liquids. Graduation is 0,001 g/cm³, enabling fine reading of specific gravity at the reference temperature of 20 °C. An integrated WG thermometer spanning 0+35 °C allows simultaneous temperature observation so that density values can be interpreted correctly. The instrument is approximately 300 mm long, giving a clear scale and comfortable immersion depth in standard cylinders. Supplied as a single piece, it is intended for routine quality control, formulation checks and educational density measurements where a narrow high-resolution range is required. Typical sample types include organic solvents, light oils and other low-density liquids that fall within 0,850–0,900 g/cm³. Manufactured by Geco-Gering, this hydrometer with built-in thermometer supports reproducible density work without separate temperature probes. The combination of DIN 12791 Serie M50 construction, fine 0,001 g/cm³ division and on-board 0+35 °C thermometer makes it a practical tool for laboratories that need reliable, temperature-aware density readings in a compact glass format.
This article is part of Hydrometers, in Density & viscosity measurement.
Key features
- Pack size: 1 pc
- Density: range: 0,850–0,900 g/cm³
- Product type: Hydrometer with thermometer
- Scale division: 0,001 g/cm³
- Reference temperature: 20 °C
- Thermometer range: 0+35 °C
Récemment consulté
Vous aimerez peut-être aussi
Browse related categories
Category
Sub-category
Catalogue
Brand
Questions about Hydrometer 0,850 - 0,900 with WG-thermometer 0+35C
What is this article?
Hydrometer 0,850 - 0,900 with WG-thermometer 0+35C is the article on this page. Luminix Health distributes Geco-Gering for laboratory use. It sits in Hydromètres, inside Mesure de densité & viscosité, in Instruments de laboratoire.
A hydrometer floats in a liquid and the stem reading is the density or a related scale such as Brix. The liquid has to be at the temperature printed on the stem, or a correction is required. A chip on the stem changes the reading. One hydrometer does not cover every density.
Density is mass divided by volume. A hydrometer floats at a depth that depends on the density of the liquid. A pycnometer is a vessel of known volume that is weighed full. Viscosity is the resistance to flow. A capillary viscometer times how long a volume takes to fall through a tube. Both measurements need a stated temperature, because liquids change density and viscosity as they warm. The units trace to the BIPM and to NIST.
Which category should I open next?
The category is Mesure de densité & viscosité. The sub-category is Hydromètres. The catalogue is Instruments de laboratoire.
Shelves beside this one are Viscosimètres and Densimètres & pycnomètres.
What should I check before I order?
When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.
How does ordering and shipping work?
Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.
Which other categories should I open?
The seven catalogues are Labware, Lab chemicals, Lab instruments, Lab consumables, Chromatography equipment, Lab safety equipment and Life Science & Microbiology.