PC8500 Portable pH/Conductivity Meter Kit, with GLP Data Management

Catalog nr. 28APE190064
APERA Instruments

Prix:
Prix réduit€690,00
Demander un devis pour commande en gros

Besoin d'une assistance technique ?

info@luminixhealth.com +32 13 30 43 61

Description

The PC8500 from Apera Instruments is a handy and easy-to-use meter for the determination of pH, conductivity (EC), TDS, salinity, ORP (electrode sold separately e.g. 301Pt-C) and temperature. It is protected by a silicone cover and is waterproof and dustproof (IP57), making it particularly well suited for field use, even in harsh environments. The 201T-F pH electrode features a unique low-resistance glass membrane for fast and accurate pH measurements. The 2031T-S conductivity electrode is based on our BPB (Brush-resistant Platinum Black) electrode technology and is characterized by its precision and very wide measuring range (0 - 200 mS/cm). Both electrodes are equipped with an integrated temperature sensor, which enables automatic temperature compensation (ATC) in each case.

The PC8500 has a memory function and GLP data management with storage for up to 500 memory groups. It can be connected to a PC or laptop via USB to either read out the memory groups or perform real-time storage.

  • Equipped with the 201T-F pH electrode and the 2031T-S conductivity electrode, each with integrated temperature sensor
  • Silicone case provides safe & firm grip and protects from shocks
  • Waterproof and dustproof (IP57) for use in harsh environments
  • Fold-out stand for convenient indoor operation
  • Quick and easy 1- to 3-point calibration
  • Large, illuminated LCD simultaneously displays conductivity value, pH value and temperature, as well as additional measurement and calibration information
  • Self-diagnosis supports calibration or troubleshooting
  • GLP data management (500 memory groups) with data output via USB, also with real-time storage function
  • BNC connector is compatible with LabSen® series electrodes for even more application possibilities

Technical Specifications
pH Measuring range -2.00 to 16.00 pH
Resolution 0.1/0.01 pH
Accuracy ±0.01 pH ±1 digit
Temperature compensation 0 to 100 ° C (automatic or manual)
calibration 1 to 3 points, automatic
mV Measuring range ±2000 mV
Resolution 0.1/1 mV
Accuracy ±0.1% F.S ±1 digit
Conductivity (EC) Measuring range 0 to 200 mS/cm:
(0.00 ~ 19.99) μS/cm;(20.0 ~ 199.9) μS/cm;
(200 ~ 1999) μS/cm; (2.00 ~ 19.99) mS/cm;
(20.0 ~ 199.9) mS/cm

TDS: 0.10 to 100 g/l
Salinity: 0.00 to 100 ppt

Resolution 0.01/0.1/1 μS/cm; 0.01/0.1 mS/cm
Accuracy ±1,0% F.S ±1 digit
Cell constant 0,1/1/10 cm-1
Temperature compensation 0 to 50 °C (automatic or manual)
calibration 1 to 3 points, automatic or manual
Temperature Measuring range 0 to 100 °C
Resolution 0,1 °C
Accuracy ±0,5 °C ±1 digit
Further Memory locations 500 records
Memory values

Numbering, date, time,

Measured value, unit, temperature

Interface USB
Power supply 3 x AA batteries / DC 5V (USB port)
Housing protection class IP57
Electrode connections

BNC (pH/ ORP), 8-pin (conductivity),

RCA (temperature)

Dimensions / Weight

88x170x33 mm / 313 g

with case: 360x270x76 mm / 1,4 kg

 

A complete set contains:

  • PC8500 pH/conductivity meter
  • 201T-F pH electrode
  • 2301T-S Conductivity electrode
  • pH calibration solution (pH 4.00; pH 7.00; pH 10.01) 50ml each
  • EC calibration solution (84 μS/cm; 1413 μS/cm; 12.88 mS/cm) 50ml each.
  • USB cable
  • USB stick with PC-Link software
  • Electrode clip
  • Screwdriver
  • Manual
  • Carrying case
 

The meter is RoHS and EC certified and has a 3 year warranty (6 months on the electrode).

Besoin d'une assistance technique ?

info@luminixhealth.com +32 13 30 43 61

Récemment consulté

Vous aimerez peut-être aussi

Questions about PC8500 Portable pH/Conductivity Meter Kit, with GLP Data Management

What is this article?

PC8500 Portable pH/Conductivity Meter Kit, with GLP Data Management is the article on this page. Luminix Health distributes APERA Instruments for laboratory use. It sits in Conductivity meters & cells, inside pH & electrochemistry, in Instruments de précision.

A conductivity meter and its cell measure how well a solution carries current. The cell constant is the geometry that converts conductance to conductivity, and it is calibrated with a standard. Temperature compensation matters because conductivity rises with temperature.

A pH meter is a voltmeter on a glass electrode. The voltage tracks hydrogen-ion activity, and the electrode is converted to pH only after it is adjusted with buffers of known value. Conductivity measures how well a solution carries a current, which for dilute salts tracks concentration. Dissolved oxygen and titration are further electrodes on the same idea: a sensor, a standard, and a reading that is only as fresh as the calibration. Buffer values and chemical identity sit on PubChem. Accreditation of the calibration laboratory is the field of BELAC and EURAMET.

Which category should I open next?
What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?