ROTIPHORESE® NF-Acrylamide/Bis solution, 40% acrylamide-/bisacrylamide, 100 ml

Catalog nr. A121.3
Carl Roth

Volume: 100 ml
Value Packs: 1 piece
Prix:
Prix réduit€32,80
Demander un devis pour commande en gros

Besoin d'une assistance technique ?

info@luminixhealth.com +32 13 30 43 61

Description

ROTIPHORESE® NF-Acrylamide/Bis solution, 40% acrylamide-/bisacrylamide, stock solution, ready-to-use, gas stabilised, fluorescence-free, Density (D) 1,03 g/cm³, Boiling point (bp) ~100 °C, Storage temp. +4 °C, UN-Nr. 3426

This article belongs on Gels, combs & casting accessories, in Electrophoresis.

Ready-to-use, gas-stabilized ready-to-use acrylamide solutions with different concentrations and ratios of acrylamide to bisacrylamide. The ROTIPHORESE® gel solutions are very easy to use and enable reproducible and high-resolution gel electrophoresis.

Directions for use

ROTIPHORESE® gel solutions can be used for protein and nucleic acid separation in PAGE gels. The high-purity solutions can be combined with any buffer system. During sequencing, they facilitate the preparation of sequencing gels of consistent quality; our fluorescence-free gel solutions are recommended for the use of automatic sequencers.

Please note

The ROTIPHORESE®acrylamide and bisacrylamide solutions from Carl ROTH are produced only from acrylic acid-free substances and are strictly controlled in acrylamide content and pH. Oxidation products are removed from the solution by a selective absorption process. Their new formation and the polymerization of the solution are prevented by stabilizing the solution with inert gas. In order to ensure a high lot-to-lot consistency of our ROTIPHORESE® solutions, each batch is subjected to an electrophoretic test. Fluorescence-free gel solutions are tested for suitability for automatic sequencers.

NF acrylamide solutions are very well suited for application in fluorescence-labelled automated sequencing, e.g. using LI-COR or ABI slab gel sequencers.

ROTIPHORESE®NF ready-to-use solutions for automated sequencing are special fluorescence-free acrylamide/bisacrylamide mixtures of highest quality as required for automatic sequencing. Made from 4x cristallised acrylamide.

Cross linking 3,3.

ROTIPHORESE®NF ready-to-use solutions are made from 4x crystallized acrylamide and are special fluorescence-free acrylamide/bisacrylamide mixtures of the highest quality, as required for automatic sequencing.

Not a medical device / Not an IVD product

Besoin d'une assistance technique ?

info@luminixhealth.com +32 13 30 43 61

Compliance & Safety Information

GHS06GHS08 Danger

Hazard Statements (H-Phrases)

H301 Toxic if swallowed
H315 Causes skin irritation
H317 May cause an allergic skin reaction
H319 Causes serious eye irritation
H332 Harmful if inhaled
H340 May cause genetic defects
H350 May cause cancer
H361f H361f – No description available
H372 Causes damage to organs through prolonged or repeated exposure

Precautionary Statements (P-Phrases)

P201 P201 – No description available
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P301+P310 P301+P310 – No description available
P302+P352 IF ON SKIN: Wash with plenty of water.
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P308+P313 IF exposed or concerned: Get medical advice/attention.

Recently viewed

You may also like

Questions about ROTIPHORESE® NF-Acrylamide/Bis solution, 40% acrylamide-/bisacrylamide, 100 ml

What is this article?

ROTIPHORESE® NF-Acrylamide/Bis solution, 40% acrylamide-/bisacrylamide, 100 ml is the article on this page. Luminix Health distributes Carl Roth for laboratory use. It sits in Gels, combs & casting accessories, inside Electrophoresis, in Microbiologie.

A gel, a comb and a casting tray make the slab a sample runs through. Agarose percentage, or the acrylamide mix, sets the sieve. The comb thickness and the number of teeth set the wells. Precast and hand-cast gels are different products. A comb for a different tray does not seal.

Electrophoresis pulls charged molecules through a gel. Smaller ones move farther. Agarose gels separate nucleic acids. Polyacrylamide gels separate proteins. A comb forms the wells. A power supply holds the voltage or the current. The gel percentage is the sieve. A marker lane is how the bands are named. The methods are in the PubMed literature. Sequences of the nucleic acids are on NCBI Nucleotide.

Which category should I open next?

The category is Electrophoresis. The sub-category is Gels, combs & casting accessories. The catalogue is Microbiologie.

Shelves beside this one are Electrophoresis systems & power supplies.

What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?