Size exclusion chromatography columns, ROTI®Dex FPLC 1 ml, 5 unit(s)

SKU: 21C6.1

Volume: 5 pc(s)
Value Packs: 1 piece
Prix:
Prix réduit€317,15

Description

Size exclusion chromatography columns, ROTI®Dex FPLC 1 ml, Density (D) ~1 g/cm³, Flash point (flp) 38 to 43 °C, Storage temp. +2 to +25 °C

Prepacked ROTI®Dex-FPLC columns for size exclusion chromatography using syringe, pump or FPLC systems, for fast and efficient removal of unwanted low molecular weight factors, such as impurities, salts, excipients, markers, cell debris, etc. from protein or nucleic acid solutions.

Suitable for:
  • 'Fast Protein Liquid Chromatography' (FPLC)
  • Common chromatographs such as ÄKTA™FPLC™
  • Syringe and peristaltic pumping systems

The purification is based on a spherical porous gel filtration medium consisting of dextran cross-linked with epichlorohydrin.

In size exclusion chromatography molecules are separated according to their size in solution. Smaller molecules pass through the column much slower than larger molecules.In contrast to other chromatography methods, no interactions occur here between the analyte and the stationary phase of the column. This provides the ideal basis for the purification and analysis of intact proteins.

Advantages:
  • Sample preparation in just a few minutes
  • Desalting, removal of impurities and buffer exchange in a single step
  • No interaction between analyte and medium
  • High selectivity, high resolution and high yield (> 95%)
  • Also suitable for small sample volumes
  • High chemical stability and therefore compatible with many organic and other solvents

The column bed consists of ROTI®Dex-25 Superfine. It is the gel filtration medium with the smallest dextran particles, which provide efficient results and very high resolutions. Biomolecules >5 kDa or >10 bp and particles >2 nm are purified. The fractionation range for proteins/peptides/biomolecules is between 1 and 5 kDa, with the highest resolution (most efficient separation) achieved between biomolecules >5 kDa and <1 kDa.

Suitable for:
  • Oligonucleotides > 10 bp
  • Globular proteins > 5 kDa
  • Particles > 2 nm

Sample volumes of 0.05-0.3 ml are recommended for the 1 ml columns.

Detailed information on the application can be found in our Technical Information Brochure and in our Instructions for Use.

Technical Information
Version 1 ml bed volume 
Matrix Cross-linked dextran 
MWCO 5 kDa10 bp
Particle size Dry: 20-50 µmWet: 40-110 µm
Storage buffer 20 % (v/v) ethanol 
Sample volume 0.05 – 0.3 ml
Max. pressure 3 bar (0.3 MPa) 
recommended flow rate 0.5 - 2 ml/min
maximum flow rate 3 ml/min
Column shape 0.7 cm inner diameter x 2.5 cm height 
Inlet connection 10–32 (1/16”) female 
Outlet connection 10–32 (1/16”) male 

Compliance & Safety Information

GHS02 Avertissement

Hazard Statements (H-Phrases)

H226 Flammable liquid and vapour

Precautionary Statements (P-Phrases)

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P501 P501 – No description available