Description
The 2401T-F conductivity electrode with temperature sensor is a laboratory electrode engineered for high-accuracy conductivity measurements. Its hollow structure and platinum chip sensor design improve accuracy and stability across the range 0 to 200 mS/cm at cell constant K = 1,0. The lead-free glass body resists general chemical corrosion, while the built-in 30KΩ thermistor measures temperature simultaneously and supports automatic temperature compensation. The electrode connects via BNC/RCA on a 1 m cable and is compatible with Apera Instruments meters EC800, EC820, PC800, PC820, EC910, PC910, EC950, PC950, EC9500 and PC9500. Electrode dimensions are Ø12 × 145 mm; recommended operating temperature is 0 to 80 °C. Offered as a single piece from manufacturer APERA Instruments, this glass-body sensor suits routine laboratory conductivity work where stable readings and integrated ATC are required. A six-month manufacturer warranty applies to the electrode.
This article is part of Conductivity meters & cells, in pH & electrochemistry. See also pH meters.
Key features
- Pack size: 1 pc
- Measuring range: 0 to 200 mS/cm
- Cell constant: K = 1,0
- Shaft material: Lead-free glass
- Connector: BNC/RCA
- Integrated temperature sensor: 30KΩ thermistor
Recently viewed
You may also like
Browse related categories
Category
Sub-category
Catalogue
Brand
Questions about 2401T-F Conductivity/Temp. Electrode
What is this article?
2401T-F Conductivity/Temp. Electrode is the article on this page. Luminix Health distributes APERA Instruments for laboratory use. It sits in Conductivity meters & cells, inside pH & electrochemistry, in Lab instruments.
A conductivity meter and its cell measure how well a solution carries current. The cell constant is the geometry that converts conductance to conductivity, and it is calibrated with a standard. Temperature compensation matters because conductivity rises with temperature.
A pH meter is a voltmeter on a glass electrode. The voltage tracks hydrogen-ion activity, and the electrode is converted to pH only after it is adjusted with buffers of known value. Conductivity measures how well a solution carries a current, which for dilute salts tracks concentration. Dissolved oxygen and titration are further electrodes on the same idea: a sensor, a standard, and a reading that is only as fresh as the calibration. Buffer values and chemical identity sit on PubChem. Accreditation of the calibration laboratory is the field of BELAC and EURAMET.
Which category should I open next?
The category is pH & electrochemistry. The sub-category is Conductivity meters & cells. The catalogue is Lab instruments.
Shelves beside this one are pH electrodes & sensors, pH meters, Dissolved oxygen & multiparameter meters, Titrators & electrochemistry systems and pH & electrochemistry accessories.
What should I check before I order?
When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.
How does ordering and shipping work?
Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.
Which other categories should I open?
The seven catalogues are Labware, Lab chemicals, Lab instruments, Lab consumables, Chromatography equipment, Lab safety equipment and Life Science & Microbiology.