Adapters for reaction vials, 0.2/0.4 ml , Suitable f. Frontier FC5513/FC5513R

Catalog nr. 23NH.1
Ohaus

Volume: 6 pc(s)
Value Packs: 1 piece
Price:
Sale price€51,00
Ask quote for bulk order

Description

Adapters for reaction vials, 0.2/0,4 ml are centrifuge accessories made to hold small reaction vials securely during microlitre centrifugation. They are sized for 0,2 ml and 0,4 ml vials, so laboratories can process limited sample volumes without switching to larger tube formats. The adapters are suitable for Frontier FC5513 and FC5513R microlitre centrifuges, supporting stable positioning of reaction vials in the rotor during routine runs. Supplied in a pack of 6 pc(s), they allow several small vials to be handled together in a single workflow. From manufacturer Ohaus, these adapters fit naturally into the Frontier microlitre centrifuge environment used in research, analytical and life-science laboratories. They belong to the labware range for laboratory appliances and centrifuge accessories, specifically within microlitre centrifuge setups. By matching the indicated vial volumes to compatible instruments, they help organise sample preparation steps that rely on compact reaction tubes. The set is intended for everyday use wherever 0,2 ml or 0,4 ml reaction vials must be centrifuged safely and consistently on the specified Frontier models.

This article is part of Rotor adapters & accessories, in Centrifuges.

Key features

  • Pack size: 6 pc(s)
  • Product type: Adapters for reaction vials
  • Vial volume: 0.2/0,4 ml
  • Compatibility: Frontier FC5513/FC5513R

Recently viewed

You may also like

Questions about Adapters for reaction vials, 0.2/0.4 ml , Suitable f. Frontier FC5513/FC5513R

What is this article?

Adapters for reaction vials, 0.2/0.4 ml , Suitable f. Frontier FC5513/FC5513R is the article on this page. Luminix Health distributes Ohaus for laboratory use. It sits in Rotor adapters & accessories, inside Centrifuges, in Lab instruments.

An adapter lets a rotor spun for large tubes accept smaller ones. The adapter has to be the one for that rotor, and the tubes have to be supported at the shoulder the adapter was designed for. A stack of the wrong inserts is an unbalanced load.

A centrifuge separates by density. The rotor spins the sample and the force is reported as a multiple of gravity, not as a raw speed, because the same revolutions per minute are a different force at a different radius. A microcentrifuge takes small tubes. A benchtop or floor model takes larger rotors. The tube, the adapter and the rotor have to be the combination the manufacturer rated. An unbalanced load is how centrifuges fail. Measurement of the related quantities sits with the BIPM.

Which category should I open next?
What should I check before I order?

The technical information on this page is the manufacturer's sheet. Read that, not a rewritten specification.

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?