Description
Density hydrometer 1,000–1,200 g/cm³ is a precision laboratory instrument for determining the density of liquids within this measuring span. The scale runs from 1,000 to 1,200 g/cm³ with a fine division of 0,002 g/cm³, supporting clear, stepwise readings across the full range. The glass body is 350 mm long and is referenced to a calibration temperature of 20 °C, the conventional basis for density work in analytical and process laboratories. An integrated thermometer covers 0 to +40 °C with 1 °C graduation and uses a red or blue special filling; the scale is arranged for bottom reading so that the meniscus can be observed consistently. Supplied as a single piece, this hydrometer is suited to routine density checks, quality control and comparative measurements on liquids whose densities fall between 1,000 and 1,200 g/cm³. Instruments of this type from manufacturer Amarell are established tools in chemical, pharmaceutical and industrial laboratories where reliable density indication and simultaneous temperature observation are required. The combined density and temperature scales allow the operator to record both parameters in one immersion, simplifying workflow when temperature-dependent density values must be noted.
This article is part of Hydrometers, in Density & viscosity measurement.
Key features
- Pack size: 1 pc
- Density: range: 1,000–1,200 g/cm³
- Length: 350 mm
- Scale division: 0,002 g/cm³
- Reference temperature: 20 °C
- Thermometer: 0 to +40 °C, division 1 °C
Recently viewed
You may also like
Questions about Density hydrometer, 1,000-1,200:0,002g/cm³, 350mm long, reference temperature
What is this article?
Density hydrometer, 1,000-1,200:0,002g/cm³, 350mm long, reference temperature is the article on this page. Luminix Health distributes Amarell for laboratory use. It sits in Hydrometers, inside Density & viscosity measurement, in Lab instruments.
A hydrometer floats in a liquid and the stem reading is the density or a related scale such as Brix. The liquid has to be at the temperature printed on the stem, or a correction is required. A chip on the stem changes the reading. One hydrometer does not cover every density.
Density is mass divided by volume. A hydrometer floats at a depth that depends on the density of the liquid. A pycnometer is a vessel of known volume that is weighed full. Viscosity is the resistance to flow. A capillary viscometer times how long a volume takes to fall through a tube. Both measurements need a stated temperature, because liquids change density and viscosity as they warm. The units trace to the BIPM and to NIST.
Which category should I open next?
The category is Density & viscosity measurement. The sub-category is Hydrometers. The catalogue is Lab instruments.
Shelves beside this one are Viscometers and Density meters & pycnometers.
What should I check before I order?
When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.
How does ordering and shipping work?
Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.
Which other categories should I open?
The seven catalogues are Labware, Lab chemicals, Lab instruments, Lab consumables, Chromatography equipment, Lab safety equipment and Life Science & Microbiology.

