Density hydrometer, 2,500-3,000:0,005g/cm³, 280-300mm long, reference

Catalog nr. H801632
Amarell

Price:
Sale price€74,90
Ask quote for bulk order

Description

Density hydrometer spanning 2,500–3,000 g/cm³ with a scale division of 0,005 g/cm³ enables precise density measurement of high-density liquids. The instrument is referenced to 20 °C and is intended for laboratory and process applications requiring reliable density values in this elevated range. Overall length is 280–300 mm (specified length 300 mm). It is supplied without a built-in thermometer, and the scale is read at the bottom of the meniscus to ensure consistent observation. This density hydrometer from manufacturer Amarell is produced in Germany and supports routine density determination in chemical, industrial and materials testing environments. Clear scale marking and the fine 0,005 g/cm³ subdivision facilitate accurate visual reading across the full measuring interval. Delivered as one piece, it is suitable for use in standard hydrometer vessels under temperature conditions aligned with the 20 °C reference. The design focuses on straightforward density assessment without integrated temperature measurement.

This article is part of Hydrometers, in Density & viscosity measurement.

Key features

  • Pack size: 1 pc
  • Scale range: 2,500–3,000 g/cm³
  • Scale division: 0,005 g/cm³
  • Length: 300 mm
  • Reference temperature: 20 °C
  • Thermometer: without thermometer

Recently viewed

You may also like

Questions about Density hydrometer, 2,500-3,000:0,005g/cm³, 280-300mm long, reference

What is this article?

Density hydrometer, 2,500-3,000:0,005g/cm³, 280-300mm long, reference is the article on this page. Luminix Health distributes Amarell for laboratory use. It sits in Hydrometers, inside Density & viscosity measurement, in Lab instruments.

A hydrometer floats in a liquid and the stem reading is the density or a related scale such as Brix. The liquid has to be at the temperature printed on the stem, or a correction is required. A chip on the stem changes the reading. One hydrometer does not cover every density.

Density is mass divided by volume. A hydrometer floats at a depth that depends on the density of the liquid. A pycnometer is a vessel of known volume that is weighed full. Viscosity is the resistance to flow. A capillary viscometer times how long a volume takes to fall through a tube. Both measurements need a stated temperature, because liquids change density and viscosity as they warm. The units trace to the BIPM and to NIST.

Which category should I open next?

The category is Density & viscosity measurement. The sub-category is Hydrometers. The catalogue is Lab instruments.

Shelves beside this one are Viscometers and Density meters & pycnometers.

What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?