LID FOR 18x2ML SPIN COLUMN ROTOR (5424)

Catalog nr. 5424707009
Eppendorf

Price:
Sale price€260,00
Ask quote for bulk order

Description

Aerosol-tight rotor lid for the F-45-18-11-Kit is a dedicated cover for spin-column and microtube centrifugation on Centrifuge 5424 and Centrifuge 5424 R. Made of polypropylene, it closes the matching 18-place rotor used with spin columns or 1,5/2,0 ml vessels and supports contained operation when aerosol-tight sealing is required. The lid is intended as a replacement or spare for the F-45-18-11-Kit rotor assembly, helping maintain correct rotor closure during routine molecular biology and sample-preparation runs. Laboratories operating 5424 series centrifuges can keep this cover on hand to restore full rotor functionality after wear or to equip an additional kit rotor. This accessory from manufacturer Eppendorf is specified for the F-45-18-11-Kit and the 5424 / 5424 R platform. Net weight is 0,090 kg, with a pack size of one piece, so storage and handling remain simple beside the centrifuge. Pairing the correct aerosol-tight lid with the spin-column rotor helps preserve safe, consistent use of the 18-place configuration in daily laboratory workflows.

This article is part of Rotors, in Centrifuges.

Key features

  • Pack size: 1 pc
  • Product type: Rotor lid
  • For rotor: F-45-18-11-Kit
  • Material: Polypropylene
  • Seal type: Aerosol-tight
  • Compatible with: Centrifuge 5424/5424 R
  • Technical Information Sheet: PDF

Recently viewed

You may also like

Questions about LID FOR 18x2ML SPIN COLUMN ROTOR (5424)

What is this article?

LID FOR 18x2ML SPIN COLUMN ROTOR (5424) is the article on this page. Luminix Health distributes Eppendorf for laboratory use. It sits in Rotors, inside Centrifuges, in Lab instruments.

A centrifuge rotor is the rotating part that holds the tubes, and it is rated for a maximum speed and a maximum load. A swing-out rotor and a fixed-angle rotor pellet differently. A rotor from another centrifuge does not belong on this drive, even when it seems to fit.

A centrifuge separates by density. The rotor spins the sample and the force is reported as a multiple of gravity, not as a raw speed, because the same revolutions per minute are a different force at a different radius. A microcentrifuge takes small tubes. A benchtop or floor model takes larger rotors. The tube, the adapter and the rotor have to be the combination the manufacturer rated. An unbalanced load is how centrifuges fail. Measurement of the related quantities sits with the BIPM.

Which category should I open next?
What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?