Portable Photometer for Ammonia Low Range with CAL Check

Catalog nr. HI97700C
Hanna Instruments

Price:
Sale price€595,00
Ask quote for bulk order

Description

Low range ammonia photometer HI97700C is a portable, battery-powered dedicated photometer supplied in a carrying case with standards for ammonia measurement from 0,00 to 3,00 mg/L as ammonia-nitrogen (NH3-N). Results may also be shown as ammonia or ammonium. Belonging to the HI97xxx series, the meter combines a sealed optical path, LED illumination and a narrow-band interference filter at 420 nm to deliver accurate, repeatable Nessler-method readings aligned with ASTM D1426. Resolution is 0,01 mg/L; accuracy at 25 °C is ±0,04 mg/L ±4 % of reading. Round cuvettes of 24,6 mm diameter locate reproducibly in the holder. CAL Check with NIST-traceable standards lets users verify performance and recalibrate when required, while the tutorial mode details every preparation step and reagent volume. GLP access to the last calibration, automatic storage of the last 50 measurements, reaction timer, battery indicator, auto shut-off and plain-language error messages support reliable routine work. This complete kit from manufacturer Hanna Instruments is suited to drinking-water, surface-water and environmental monitoring of low ammonia levels.

This article is part of Photometers & spectrophotometers, in Spectroscopy & photometry.

Key features

  • Pack size: 1 pc
  • Configuration: carrying case, including standards
  • Measuring range: 0,00–3,00 mg/L (as NH3-N)
  • Resolution: 0,01 mg/L
  • Accuracy (25 °C): ±0,04 mg/L ±4 % of reading
  • Method: Nessler method (ASTM D1426)

Recently viewed

You may also like

Questions about Portable Photometer for Ammonia Low Range with CAL Check

What is this article?

Portable Photometer for Ammonia Low Range with CAL Check is the article on this page. Luminix Health distributes Hanna Instruments for laboratory use. It sits in Photometers & spectrophotometers, inside Spectroscopy & photometry, in Lab instruments.

A photometer reads absorbance at one or a few wavelengths. A spectrophotometer scans or selects many. Both send light through a cuvette or a well. The wavelength range, UV or visible, and the bandwidth decide what can be measured. A visible-only instrument cannot read a nucleic acid at 260 nm.

A photometer or spectrophotometer sends light through a sample and reads how much was absorbed. In the range where the Beer–Lambert relation holds, absorbance tracks concentration. A refractometer reads how a liquid bends light, which tracks dissolved solids. A polarimeter reads the rotation of polarised light, the classical measurement for sugars. The lamp, the wavelength and the cuvette path length are the three things that have to be right before the number means anything. The optical quantities trace to NIST and the BIPM.

Which category should I open next?

The category is Spectroscopy & photometry. The sub-category is Photometers & spectrophotometers. The catalogue is Lab instruments.

Shelves beside this one are Refractometers & polarimeters and Lamps, cuvette holders & accessories.

What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?