Rubber mats 15ml tubes rotor A-8-17 (8x)

Catalog nr. 5702701009
Eppendorf

Price:
Sale price€20,33
Ask quote for bulk order

Description

Rubber form insert 15 ml is a rubber mat for one 15 mL round-bottom vessel, specified for rotor A-8-17 and supplied as a pack of eight pieces. Each mat seats a single round-bottom tube so that the vessel sits securely in the rotor during centrifugation. The eight-piece pack gives laboratories ready spares or enough inserts for multi-position use on compatible rotors. Soft rubber construction cushions glass or similar round-bottom formats and supports stable alignment in the rotor bore. These form inserts fit centrifuge accessory workflows that process 15 mL round-bottom vessels and are intended specifically for the A-8-17 rotor geometry. Pack net weight is 0,018 kg and gross weight 0,020 kg, with a packaging volume of 0,001 m³, so the set stores easily with other rotor accessories. Origin is Germany (Saxony). The product is offered from manufacturer Eppendorf as a dedicated centrifuge accessory for routine sample handling. Dual-use classification does not apply. Select this pack when you need matched rubber mats for 15 mL round-bottom vessels on rotor A-8-17.

This article is part of Rotor adapters & accessories, in Centrifuges.

Key features

  • Pack size: 8 pc(s)
  • Product type: Rubber mat / form insert
  • Vessel format: 15 mL round-bottom (1 vessel per mat)
  • Compatible rotor: A-8-17
  • Technical Information Sheet: PDF

Recently viewed

You may also like

Questions about Rubber mats 15ml tubes rotor A-8-17 (8x)

What is this article?

Rubber mats 15ml tubes rotor A-8-17 (8x) is the article on this page. Luminix Health distributes Eppendorf for laboratory use. It sits in Rotor adapters & accessories, inside Centrifuges, in Lab instruments.

An adapter lets a rotor spun for large tubes accept smaller ones. The adapter has to be the one for that rotor, and the tubes have to be supported at the shoulder the adapter was designed for. A stack of the wrong inserts is an unbalanced load.

A centrifuge separates by density. The rotor spins the sample and the force is reported as a multiple of gravity, not as a raw speed, because the same revolutions per minute are a different force at a different radius. A microcentrifuge takes small tubes. A benchtop or floor model takes larger rotors. The tube, the adapter and the rotor have to be the combination the manufacturer rated. An unbalanced load is how centrifuges fail. Measurement of the related quantities sits with the BIPM.

Which category should I open next?
What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?