Cu 800 DIN, Combined Copper ion selective electrode, with 3.3 ft (1 m) cable, DI

Catalog nr. 106665
WTW - a Xylem brand

Price:
Sale price€1.812,00
Ask quote for bulk order

Description

Cu 800 DIN is a copper ion-selective combination electrode fitted with a 1 m DIN cable for accurate determination of copper ions in aqueous samples. Covering a measuring range from 0,0006 to 6400 mg/l, this single-rod measuring chain integrates the ion-selective sensor and reference system in one compact probe. Correct operation requires ELY/BR/503 reference electrolyte, ISA/FK ionic strength adjustment solution and ES/Cu standard solution; the reference electrolyte is included in the delivery. The electrode is well suited to water analysis, environmental monitoring and industrial quality-control laboratories that need selective copper ion readings. Connected via the DIN plug to compatible meters, it supports routine ion-selective measurements across a wide concentration window. Supplied as a single piece from manufacturer WTW - a Xylem brand, the Cu 800 DIN combination electrode simplifies handling while delivering reliable analytical performance for copper ion sensing in demanding laboratory workflows.

This article is part of pH electrodes & sensors, in pH & electrochemistry.

Key features

  • Pack size: 1 pc
  • Cable: 1 m DIN
  • Measuring range: 0,0006–6400 mg/l
  • Reference electrolyte: ELY/BR/503 (included)
  • Ionic strength adjuster: ISA/FK
  • EAN: 4064664001274
  • Technical Information Sheet: PDF

Recently viewed

You may also like

Questions about Cu 800 DIN, Combined Copper ion selective electrode, with 3.3 ft (1 m) cable, DI

What is this article?

Cu 800 DIN, Combined Copper ion selective electrode, with 3.3 ft (1 m) cable, DI is the article on this page. Luminix Health distributes WTW - a Xylem brand for laboratory use. It sits in pH electrodes & sensors, inside pH & electrochemistry, in Lab instruments.

A pH electrode is a glass membrane and a reference. It is a consumable: the glass ages, the junction clogs, and the reading drifts. A refillable electrode and a gel electrode differ in how they are maintained. The connector has to match the meter. The electrode, not the meter, is usually what is wrong.

A pH meter is a voltmeter on a glass electrode. The voltage tracks hydrogen-ion activity, and the electrode is converted to pH only after it is adjusted with buffers of known value. Conductivity measures how well a solution carries a current, which for dilute salts tracks concentration. Dissolved oxygen and titration are further electrodes on the same idea: a sensor, a standard, and a reading that is only as fresh as the calibration. Buffer values and chemical identity sit on PubChem. Accreditation of the calibration laboratory is the field of BELAC and EURAMET.

Which category should I open next?
What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?