Titrators & electrochemistry systems

Here you will find everything your laboratory needs for titrators and electrochemistry systems, such as: karl fischer, microelectrode and trace. This range is for biotech, hospitals, R&D, teaching and (quality) control. This collection holds 144 articles. The catalogue holds more than 150.000 articles. In-stock articles ship in two to five business days.

144 products

Showing 1 - 24 of 144 products

Showing 1 - 24 of 144 products
View
Carousel, ElectraSyn 2.0 attachment for multiple measurements, IKA, art. 0020017512IKA
Calibration cap for ElectraSyn 2.0, IKA, art. 0040007388IKA
Magnesium microelectrode for ElectraSyn 2.0, 12 pieces set, IKA, art. 0040004025IKA
Niobium microelectrode for ElectraSyn 2.0, set of 2, IKA, art. 0040004032IKA
Tin microelectrode for ElectraSyn 2.0, IKA, art. 0040004037IKA
Lead bronze microelectrode for ElectraSyn 2.0, set of 12, IKA, art. 0040004030IKA
Microelectrode cobalt, microelectrode for ElectraSyn 2.0, IKA, art. 0040004039IKA
Silver microelectrode for ElectraSyn 2.0, IKA, art. 0040004035IKA
Titanium microelectrode for ElectraSyn 2.0, set of 12, IKA, art. 0040004033IKA
Zinc microelectrode for ElectraSyn 2.0, 12 pieces set, IKA, art. 0040004026IKA
Microelectrode nickel foam, microelectrode for ElectraSyn 2.0, IKA, art. 0040004101IKA

Recently viewed

Questions about Titrators & electrochemistry systems

Why Titrators & electrochemistry systems?

A titrator adds a reagent and watches an electrode until an endpoint, then calculates the amount. It is a burette, a stirrer and a meter in one. The electrode and the reagent concentration still decide the result. A manual titration is the same chemistry without the automation.

A pH meter is a voltmeter on a glass electrode. The voltage tracks hydrogen-ion activity, and the electrode is converted to pH only after it is adjusted with buffers of known value. Conductivity measures how well a solution carries a current, which for dilute salts tracks concentration. Dissolved oxygen and titration are further electrodes on the same idea: a sensor, a standard, and a reading that is only as fresh as the calibration. Buffer values and chemical identity sit on PubChem. Accreditation of the calibration laboratory is the field of BELAC and EURAMET.

This shelf belongs to pH & electrochemistry, inside Lab instruments. Luminix Health distributes this range for laboratory use.

Which shelves sit beside this one?
How does ordering and shipping work?

Luminix Health distributes this range from the heart of Europe. We deliver across the EU in two to five days if in stock. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. Send a quote request, contact the team, or read who we are. The full brand index is on shop by brand.

Which other categories should I open?