Beschrijving
A 11.6 is a double-beater grinding tool manufactured from surface-hardened titanium for use exclusively with the A 11.4 grinding beaker. Suitable for materials up to Mohs hardness 3, the beater delivers efficient comminution of soft to medium-hard samples in analytical milling applications. The titanium construction combines low weight with good wear resistance, supporting reproducible particle-size reduction in laboratory sample preparation. This accessory is not included in the standard delivery of the A 11 basic mill and must be ordered separately. Supplied as a single piece from manufacturer IKA, the double beater integrates directly into the A 11 system when the matching beaker is fitted. Compact dimensions and a net weight of only 0,026 kg simplify handling and storage. Ideal for laboratories performing routine grinding of organic and inorganic materials that do not exceed the specified hardness limit.
This article is part of Mills, grinders & homogenisers, in Test sieves & mills.
Key features
- Pack size: 1 pc
- Storage temperature: 5°C - 40°C
- Material: Titanium, surface-hardened
- Hardness suitability: Up to Mohs hardness 3
- Compatibility: Grinding beaker A 11.4 only
- EAN: 4053411004972
Recent bekeken
Misschien vind je dit ook leuk
Questions about A 11.6, Double beater, titanium
What is this article?
A 11.6, Double beater, titanium is the article on this page. Luminix Health distributes IKA for laboratory use. It sits in Mills, grinders & homogenisers, inside Test sieves & mills, in Instrumenten.
A mill, grinder or homogeniser reduces particle size or breaks a tissue before an extraction. The rotor and the sieve insert decide the result. A knife mill and a bead mill are different machines. The sample has to tolerate the heat the motor puts into it.
A test sieve sorts particles by whether they pass an opening. Wire mesh and perforated plate are two ways of making that opening, and the nominal size is not a suggestion. A sieve shaker repeats the motion so the result does not depend on how hard someone shook by hand. A mill or grinder makes the particles smaller before they are sieved. The certificate of the sieve, and the opening size, are what an audit asks for. Measurement practice around mass and dimension sits with the BIPM, EURAMET and BELAC.
Which category should I open next?
The category is Test sieves & mills. The sub-category is Mills, grinders & homogenisers. The catalogue is Instrumenten.
Shelves beside this one are Test sieves (wire mesh), Test sieves (perforated plate), Sieve shakers and Sieve accessories (lids, pans, rings).
What should I check before I order?
When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.
How does ordering and shipping work?
Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.
Which other categories should I open?
The seven catalogues are Labware, Lab chemicals, Lab instruments, Lab consumables, Chromatography equipment, Lab safety equipment and Life Science & Microbiology.

