Description
Density hydrometer for liquid density measurement over the scale range 0,600–0,700 g/cm³ with a scale division of 0,001 g/cm³. The instrument is 300 mm long and is calibrated to a reference temperature of 20 °C, without an integrated thermometer; density values are read at the bottom. Supplied as 1 pc, this density hydrometer from manufacturer Amarell is suited to manual immersion determinations on lower-density liquids within the stated interval. The 0,600–0,700 g/cm³ span with 0,001 g/cm³ division offers fine resolution across a compact low-density window, while the 300 mm length supports stable flotation and clear scale observation in an appropriate measuring cylinder. Absence of a built-in thermometer keeps the design focused on density readout alone, with temperature control or separate measurement handled externally as required by the method. Bottom reading and the 20 °C reference temperature complete the metrological specification, giving laboratories a straightforward araeometer for density checks of light liquids referenced to 20 °C.
This article is part of Hydrometers, in Density & viscosity measurement.
Key features
- Pack size: 1 pc
- Density: range: 0,600–0,700 g/cm³
- Scale division: 0,001 g/cm³
- Length: 300 mm
- Reference temperature: 20 °C
- Thermometer: without thermometer
Recently viewed
You may also like
Questions about Density hydrometer, 0,600-0,700:0,001g/cm³, 300mm long, reference temperature
What is this article?
Density hydrometer, 0,600-0,700:0,001g/cm³, 300mm long, reference temperature is the article on this page. Luminix Health distributes Amarell for laboratory use. It sits in Hydrometers, inside Density & viscosity measurement, in Lab instruments.
A hydrometer floats in a liquid and the stem reading is the density or a related scale such as Brix. The liquid has to be at the temperature printed on the stem, or a correction is required. A chip on the stem changes the reading. One hydrometer does not cover every density.
Density is mass divided by volume. A hydrometer floats at a depth that depends on the density of the liquid. A pycnometer is a vessel of known volume that is weighed full. Viscosity is the resistance to flow. A capillary viscometer times how long a volume takes to fall through a tube. Both measurements need a stated temperature, because liquids change density and viscosity as they warm. The units trace to the BIPM and to NIST.
Which category should I open next?
The category is Density & viscosity measurement. The sub-category is Hydrometers. The catalogue is Lab instruments.
Shelves beside this one are Viscometers and Density meters & pycnometers.
What should I check before I order?
When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.
How does ordering and shipping work?
Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.
Which other categories should I open?
The seven catalogues are Labware, Lab chemicals, Lab instruments, Lab consumables, Chromatography equipment, Lab safety equipment and Life Science & Microbiology.