Description
Density hydrometer 1,100–1,200:0,001 g/cm³ is a precision glass instrument for determining liquid density over the stated scale range with a scale division of 0,001 g/cm³. The hydrometer measures 350 mm in length and is calibrated to a reference temperature of 20 °C. It incorporates an integrated thermometer covering 0+40:1 °C with red or blue special filling, and the scale is arranged for reading from below. This density hydrometer from manufacturer Amarell is supplied as a single piece and is intended for laboratory density measurements where simultaneous temperature indication is useful. The combination of a fine 0,001 g/cm³ graduation, defined reference temperature and built-in thermometer supports consistent readings across the 1,100 to 1,200 g/cm³ interval. Clear scale limits and length specification simplify matching the instrument to sample vessels and measurement protocols used in analytical and quality-control work.
This article is part of Hydrometers, in Density & viscosity measurement.
Key features
- Pack size: 1 pc
- Scale start value: 1,100
- Scale end value: 1,200
- Scale division: 0,001 g/cm³
- Length: 350 mm
- Reference temperature: 20 °C
Recently viewed
You may also like
Questions about Density hydrometer, 1,100-1,200:0,001g/cm³, 350mm long, reference temperature
What is this article?
Density hydrometer, 1,100-1,200:0,001g/cm³, 350mm long, reference temperature is the article on this page. Luminix Health distributes Amarell for laboratory use. It sits in Hydrometers, inside Density & viscosity measurement, in Lab instruments.
A hydrometer floats in a liquid and the stem reading is the density or a related scale such as Brix. The liquid has to be at the temperature printed on the stem, or a correction is required. A chip on the stem changes the reading. One hydrometer does not cover every density.
Density is mass divided by volume. A hydrometer floats at a depth that depends on the density of the liquid. A pycnometer is a vessel of known volume that is weighed full. Viscosity is the resistance to flow. A capillary viscometer times how long a volume takes to fall through a tube. Both measurements need a stated temperature, because liquids change density and viscosity as they warm. The units trace to the BIPM and to NIST.
Which category should I open next?
The category is Density & viscosity measurement. The sub-category is Hydrometers. The catalogue is Lab instruments.
Shelves beside this one are Viscometers and Density meters & pycnometers.
What should I check before I order?
When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.
How does ordering and shipping work?
Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.
Which other categories should I open?
The seven catalogues are Labware, Lab chemicals, Lab instruments, Lab consumables, Chromatography equipment, Lab safety equipment and Life Science & Microbiology.

