Description
Density hydrometer for the measuring range 1,250–1,500 g/cm³ with a scale division of 0,005 g/cm³ is a glass instrument for direct determination of liquid density. The unit is 180 mm long and is referenced to a calibration temperature of 20 °C. It is supplied without an integrated thermometer and is intended for bottom reading of the scale. This density hydrometer from manufacturer Amarell is suited to laboratory and process checks where the stated span and graduation are required. The 0,005 g/cm³ division supports clear reading across the full interval from 1,250 to 1,500 g/cm³. Compact length of 180 mm fits standard hydrometer cylinders and sample vessels used for density work at the reference temperature. Offered as a single piece and originating from Germany, the instrument belongs to the hydrometer category for routine density measurement of liquids. Scale start value 1,250 and end value 1,500 define the working window without additional measuring elements on the stem.
This article is part of Hydrometers, in Density & viscosity measurement.
Key features
- Pack size: 1 pc
- Length: 180 mm
- Measuring range: 1,250–1,500 g/cm³
- Scale division: 0,005 g/cm³
- Reference temperature: 20 °C
- Thermometer: without
Recently viewed
You may also like
Questions about Density hydrometer, 1,250-1,500:0,005g/cm³, 180mm long, reference temperature
What is this article?
Density hydrometer, 1,250-1,500:0,005g/cm³, 180mm long, reference temperature is the article on this page. Luminix Health distributes Amarell for laboratory use. It sits in Hydrometers, inside Density & viscosity measurement, in Lab instruments.
A hydrometer floats in a liquid and the stem reading is the density or a related scale such as Brix. The liquid has to be at the temperature printed on the stem, or a correction is required. A chip on the stem changes the reading. One hydrometer does not cover every density.
Density is mass divided by volume. A hydrometer floats at a depth that depends on the density of the liquid. A pycnometer is a vessel of known volume that is weighed full. Viscosity is the resistance to flow. A capillary viscometer times how long a volume takes to fall through a tube. Both measurements need a stated temperature, because liquids change density and viscosity as they warm. The units trace to the BIPM and to NIST.
Which category should I open next?
The category is Density & viscosity measurement. The sub-category is Hydrometers. The catalogue is Lab instruments.
Shelves beside this one are Viscometers and Density meters & pycnometers.
What should I check before I order?
When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.
How does ordering and shipping work?
Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.
Which other categories should I open?
The seven catalogues are Labware, Lab chemicals, Lab instruments, Lab consumables, Chromatography equipment, Lab safety equipment and Life Science & Microbiology.