Hot air steriliser SN75, 74l, 20-250°C

Catalog nr. SN75
Memmert

Price:
Sale price€1.864,00
Ask quote for bulk order

Description

Hot air sterilizer SN75 is a medical-device hot-air sterilizer with natural convection and a nominal volume of 74 l. The working temperature range extends from at least 5 °C above ambient up to +250 °C, and the set temperature range is +20 °C to +250 °C. The unit is fitted with SingleDISPLAY ControlCOCKPIT, two grid shelves and a stainless steel door, plus an electronically adjustable exhaust air flap settable from 0 % to 100 % in 10 % steps. Protocol data can be read via the Ethernet interface. Double overtemperature protection and an integrated data logger with storage capacity for at least 10 years support documented runs; three calibration values are adjustable at the ControlCOCKPIT. A factory calibration certificate for +160 °C is supplied. Structured stainless steel housing measures 585 × 944 × 514 mm, with a stainless steel interior of 400 × 560 × 330 mm. Electrical supply is 230 V, 50/60 Hz and maximum power consumption is approximately 2500 W. This sterilizer from manufacturer Memmert is suited to laboratory and medical applications that require larger-capacity controlled hot-air sterilization.

This article is part of Autoclaves & sterilisers, in Heating, drying & cooling.

Key features

  • Pack size: 1 pc
  • Nominal volume: 74 l
  • Set temperature range: +20 °C to +250 °C
  • Convection: Natural
  • Display: SingleDISPLAY
  • Material: Stainless steel
  • Technical Information Sheet: PDF

Recently viewed

You may also like

Questions about Hot air steriliser SN75, 74l, 20-250°C

What is this article?

Hot air steriliser SN75, 74l, 20-250°C is the article on this page. Luminix Health distributes Memmert for laboratory use. It sits in Autoclaves & sterilisers, inside Heating, drying & cooling, in Lab instruments.

An autoclave sterilises with steam under pressure, typically 121 °C. A load that is wrapped wrong, or a liquid in a sealed full bottle, does not see that temperature, or it bursts. Chamber volume and the cycles it can run are the specification.

Temperature equipment either holds a set point or drives a sample toward one. An oven dries. A furnace reaches the temperatures of ashing and melting. A bath surrounds a vessel with water or oil. A circulator moves that fluid. An incubator holds the mild warmth of a culture. An autoclave uses steam under pressure to sterilise. The number that matters is the temperature the article actually reaches, not the number painted on the dial. Temperature is part of the international system kept by the BIPM and compared by EURAMET.

Which category should I open next?
What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?