Laboratory refrigerators & freezers

Here you will find everything your laboratory needs for laboratory refrigerators and freezers, such as: laboratory refrigerator, laboratory refrigerator with forced-air, flake ice machine and freeze boxes. This range is for biotech, hospitals, R&D, teaching and (quality) control. This collection holds 243 articles. The catalogue holds more than 150.000 articles. In-stock articles ship in two to five business days.

243 products

Showing 1 - 24 of 243 products

Showing 1 - 24 of 243 products
View
LAUDA Versafreeze VF 70085 Ultra-Low Temperature Freezer 230 V; 50 Hz, water-cooled condenser, art. L003445Lauda
LAUDA Versafreeze VF 60040 ultra-low temperature freezer 230 V; 50 Hz, art. L003474Lauda
LAUDA Versafreeze VF 60085 Ultra-Low Temperature Freezer 230 V; 50 Hz, with 5 stainless-steel drawers, art. L003447Lauda
LAUDA Versafreeze VF 70085 ultra-low temperature freezer 230 V; 50 Hz, art. L003448Lauda
LAUDA Versafreeze VF 15085 ultra-low temperature freezer 230 V; 50 Hz, art. L003344Lauda
LAUDA Versafreeze VF 70085 Ultra-Low Temperature Freezer 230 V; 50 Hz, art. L003346Lauda
LAUDA Versafreeze VF 70040 ultra-low temperature freezer 230 V; 50 Hz, art. L003343Lauda
LAUDA Versafreeze VF 60085 ultra-low temperature freezer 230 V; 50 Hz, art. L003345Lauda
LAUDA Versafreeze VF 60040 Ultra-Low Temperature Freezer 230 V; 50 Hz, art. L003342Lauda
LAUDA Versafreeze VF 55085 C ultra-low temperature chest freezer 230 V; 50 Hz, art. L003339Lauda
LAUDA Versafreeze VF 15040 Ultra-Low Temperature Freezer 230 V; 50 Hz, art. L003341Lauda
LAUDA Versafreeze VF 75085 C Ultra-Low Temperature Chest Freezer 230 V; 50 Hz, art. L003340Lauda
LAUDA Versafreeze VF 75040 C low-temperature chest freezer 230 V; 50 Hz, art. L003337Lauda
LAUDA Versafreeze VF 20040 C ultra-low temperature chest freezer 230 V; 50 Hz, art. L003335Lauda
LAUDA Versafreeze VF 20085 C ultra-low temperature chest freezer 230 V; 50 Hz, art. L003338Lauda
LAUDA Versafreeze VF 55040 C ultra-low temperature chest freezer 230 V; 50 Hz, art. L003336Lauda
Flake ice machine with ice storage tank SCOTSMAN® AF 157 OX, art. 1TC3.1Scotsman
neoChoice Refrigerator Thermometer, neoLab, art. 12051neolab

Recently viewed

Questions about Laboratory refrigerators & freezers

Why a laboratory refrigerator instead of a household one?

Laboratory refrigerators use forced air circulation for an even temperature throughout the cabinet, recover faster after the door is opened, have alarms and often a lock. A household fridge lacks these features and its temperature can vary between shelves. If you store flammable substances, you need a spark-free interior. Lab models also suit continuous use with frequent door openings. For independent records, see data loggers. For a quote or a second opinion, write to sales@luminixhealth.com.

When do I need a spark-free (explosion-proof) refrigerator?

As soon as you store flammable solvents or reagents cold. Vapours in an ordinary fridge can be ignited by the thermostat or the light switch. A spark-free interior protects against ignition inside the cabinet, while an explosion-proof version can also protect the surrounding room. Base the choice on your own risk assessment. Store only tightly closed containers, so vapour does not build up in the cabinet. For storage at room temperature, see safety cabinets for flammables and chemicals. Questions about a specific product? Contact sales@luminixhealth.com.

Which temperature range: refrigerator, -20 °C, -40 °C or -80 °C?

Refrigerated storage suits reagents and media. A standard freezer suits enzymes and many routine samples. Low-temperature and ultra-low-temperature freezers are for long-term storage of biological material, where degradation must be kept to a minimum. Check the exact range on the product page and compare it with your samples. Leave space around the unit for ventilation. Storage boxes and racks are in cryo boxes, racks and freezer storage. Unsure which one fits? Ask sales@luminixhealth.com.

How do I monitor the temperature in my refrigerator or freezer?

Use the built-in display and alarm, plus an independent thermometer or data logger. A probe in a bottle or glycol-filled sensor shows a realistic product temperature, because it does not react to every brief door opening. Read and record the values at fixed times, or let a logger do it. Place the probe away from the walls and the door. See data loggers and digital thermometers. Need advice for your set-up? Mail sales@luminixhealth.com.

Why Laboratory refrigerators & freezers?

A laboratory refrigerator or freezer holds reagents and samples at a stated temperature, often with an alarm and a spark-free interior when solvent is stored. A domestic fridge has neither the alarm nor, usually, the spark-free claim. The set point and the volume are the specification.

Temperature equipment either holds a set point or drives a sample toward one. An oven dries. A furnace reaches the temperatures of ashing and melting. A bath surrounds a vessel with water or oil. A circulator moves that fluid. An incubator holds the mild warmth of a culture. An autoclave uses steam under pressure to sterilise. The number that matters is the temperature the article actually reaches, not the number painted on the dial. Temperature is part of the international system kept by the BIPM and compared by EURAMET.

This shelf belongs to Heating, drying & cooling, inside Lab instruments. Luminix Health distributes this range for laboratory use.

Which shelves sit beside this one?
How does ordering and shipping work?

Luminix Health distributes this range from the heart of Europe. We deliver across the EU in two to five days if in stock. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. Send a quote request, contact the team, or read who we are. The full brand index is on shop by brand.

Which other categories should I open?